Empire Heating Systems RH-25 Owner'S Manual Download Page 1

VENTED

ROOM HEATER

MODELS

RH-25

RH-35

INSTALLATION  INSTRUCTIONS

AND

OWNER’S  MANUAL

WARNING: If not installed, operated and 

maintained in accordance with the manu-

facturer’s instructions, this product could 

expose  you  to  substances  in  fuel  or  from 

fuel combustion which can cause death or 

serious illness.

Installer:  Leave this manual with the appli-

ance.

Consumer: Retain this manual for future refer-

ence.

—  Do not store or use gasoline or other flamma-

ble vapors and liquids in the vicinity of this or 

any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately call your gas supplier from a 

neighbor’s  phone.  Follow  the  gas  suppli-

er’s instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

—  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING: If the information in these instruc-

tions are not followed exactly, a fire or explosion 

may result causing property damage, personal 

injury or loss of life.

Page 1

Summary of Contents for RH-25

Page 1: ...mma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Page 2: ...ng 7 Vent Safety Shutoff System 8 Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Mainte...

Page 3: ...passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the ow of combustion and ventilation air See clearances DO keep the appliance area clear and free...

Page 4: ...form service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls...

Page 5: ...r Floor pad is available from Empire Comfort Systems Inc Part Number DVP 1 Quali ed Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair an...

Page 6: ...pped on the bottom in which condensation and foreign particles may collect Figure 2 Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System 1 To check the inlet pres...

Page 7: ...n in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brickorstoneconstructionwithouttightstormw...

Page 8: ...the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switch hole cov...

Page 9: ...oximately 60 seconds There will be an audible click when the safety magnet in the gas control is de energized Pilot can now be relit Repeat steps 5 through 10 12 Turn gas control knob counterclockwise...

Page 10: ...will be a short blue inner ame with a larger lighter blue secondary ame The burner ame may have yellow tips when hot Dust in the combustion air will produce an orange or red ame Do not mistake the ora...

Page 11: ...hen knob is released a Pilot ame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat control a Thermostat needs calibrat...

Page 12: ...Burner RH 35 6 24 R 1195 Thermocouple 36 25 R 1227 Pilot Burner with Ori ce Nat 25 R 1228 Pilot Burner with Ori ce LPG 26 11698 Pilot Tubing 27 R 6120 Electrode and Wire Assembly USE ONLY MANUFACTURER...

Page 13: ...12821 8 0907 Page 13 PARTS VIEW...

Page 14: ...g front Attention Wiring harness on blower is factory assembled and installed If wiring harness becomes disassembled use the follow ing steps to reassemble the wiring harness 1 Attach 1 pinterminalfro...

Page 15: ...rature dial or thermostat to lowest setting 2 Turn knob on gas control to OFF depressing slightly Do not force Cleaning The blower wheel will collect lint and could require cleaning once a year If the...