THIS IS A HEATING APPLIANCE

DO NOT OPeRaTe THIS aPPLIaNCe WITHOUT FRONT PaNeL INSTaLLeD.

•  Due to high temperatures the appliance should be located 

out of traffic and away from furniture and draperies.

•  Children and adults should be alerted to the hazards of 

high surface temperatures and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same room as the appliance.

•  Clothing or other flammable material should not be placed 

on or near the appliance.

•  Any  safety  screen  or  guard  removed  for  servicing  an 

appliance  must  be  replaced  prior  to  operating  the 

appliance.

•  Keep burner and control compartment clean.  
•  Vent cap hot while furnace is in operation.
• 

Installation and repair should be done by a qUALIFIED 

SERVICE PERSON.   The appliance should be inspected 

before use and at least  annually by  a qualified service 

person.  More frequent cleaning may be required due  to 

excessive lint from carpeting, bedding materials, etc.  It 

is  imperative  that  control  compartments,  burners    and 

circulating  air  passageways  of  the  appliance  be  kept 

clean.

•  Do not 

put anything around the furnace that will obstruct 

the flow of combustion and ventilation air.

•  Do

 keep the appliance area clear and free from combustible 

material,  gasoline  and  other  flammable  vapors  and 

liquids.

•  Do

  examine  venting  system  periodically  and  replace 

damaged parts.

•  Do 

make a periodic visual check of pilot and burners. 

Clean and replace damaged parts.

•  CAUtIon:  Pilot hole cover must be kept tightly closed 

during operation.

•  Do not 

use this heater if any part has been under water.  

Immediately call a qualified service technician to inspect 

the heater and to replace any part of the control system 

and any gas control which has been under water. 

attention: The  DV-55IPT direct vent wall furnaces are provided with vent kit, DV4T-59-1 for wall depths of 5" to 9". For wall depths 

greater than 9", refer to accessories, Page 6. Listed below are the vent kits.
attention: The minimum wall depth for installation of a  DV-55IPT 

MUST BE 5"

. If the wall depth is less than 5" you can order DV-

822, refer to accessories, Page 6 or refer to Figure 10 and Figure 11 with accompanying text, Page 11.

NO.

PART DESCRIPTION

VEnt KItS

DV4T-59-1

DV4T-812-1 DV4T-1219-1

1

OUTLeT TUBe - INNeR

13057

13057

13058

2

GaSKeT - OUTeR COLLaR

M-177

M-177

M-177

3

OUTLeT TUBe - INNeR

13104

13104

13105

4

INLeT TUBe - INNeR

13062

13062

13063

5

GaSKeT - INLeT COLLaR

M-178

M-178

M-178

6

INLeT TUBe - INNeR

13106

13106

13107

7

INLeT TUBe - OUTeR

13064

13065

13066

8

OUTLeT TUBe - OUTeR

13059

13060

13061

9

VeNT CaP

13053

13053

16053

HaRDWaRe KIT

13078

13078

13078

IMPORTANT SAFETY INFORMATION

VEnt KIt InFoRMAtIon

Summary of Contents for DV-55IPT-1

Page 1: ...ath or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vici...

Page 2: ...6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and Mainte...

Page 3: ...arandfreefromcombustible material gasoline and other flammable vapors and liquids Do examine venting system periodically and replace damaged parts Do make a periodic visual check of pilot and burners...

Page 4: ...lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorptio...

Page 5: ...torasrequiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to t...

Page 6: ...alled so that all burners and burner ignition devices are located not less than 18 above the floor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehi...

Page 7: ...ame to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will...

Page 8: ...t kits for wall depths of 8 to 12 or 12 to 19 The use of tubes not supplied by the manufacturer results in unsatisfactory performance 3 The DV 55IPT can be attached to the wall or recessed into the wa...

Page 9: ...ide outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adjacent wall...

Page 10: ...ntrol compartment bottom of the furnace Please remove 7 8 knockout from appropriate side panel when routing plug assembly to an electrical outlet Installation of Three prong Grounding Plug Assembly 1...

Page 11: ...nlet and the flue outlet portions of the vent Any wall projection such as a door or window casing which disturbs the wind on one side of the air inlet section will result in back pressure on the flue...

Page 12: ...ice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 Stop Read the safety information above 2 Set the thermostat to lo...

Page 13: ...ilot flame and the spark gap are factory checked and tested After use cleaning may be required for the proper flame The correct flame will be a short blue inner flame with a much larger light blue out...

Page 14: ...sed plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw With this wire completing the ground the appliance cord plug can be plugged into the adapter and be e...

Page 15: ...switch type 24 Vac thermostats capable of supplying rated voltage and current to the module AMBIENT TEMPERATURE RATING Minus 40 F to plus 175 F minus 40 C to plus 79 C RELATIVE HUMIDITY RATING 5 to 9...

Page 16: ...ALVE PILOT OPERATOR OPENS PILOT BURNER OPERATION PILOT BURNER LIGHTS MODULE SENSES FLAME CURRENT PILOT BURNER DOES NOT LIGHT OR MODULE RESPONSE S8600H AFTER90SECONDS PILOTVALVE CLOSES SPARKSTOPS LOCKO...

Page 17: ...ion cable or other heavily insulated wire A Close the manual gas valve B Disconnect the ignition cable at the SPARK terminal on the module Warning Whenperformingthefollowingsteps donottouchstripped en...

Page 18: ...orrect Check boot of the ignition cable for signs of melting or buckling Take protective action to shield cable and boot from excessive temperatures Check for 24 VAC across MV MV PV terminals If no vo...

Page 19: ...NEL LOWER 29 DV 826 REAR BURNER ASSEMBLY 30 R 1617 SPARK PLUG WIRE 31 R 714 L PILOT WITH ORIFICE LPG GAS 31 R 714 N PILOT WITH ORIFICE NAT GAS 32 DV 808 PILOT TUBING 33 DV 824 FRONT BURNER ASSEMBLY 34...

Page 20: ...13281 9 0709 Page 20 PARTS VIEW...

Page 21: ...m Parts Heater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites...

Page 22: ...13281 9 0709 Page 22 SERVICE NOTES...

Page 23: ...13281 9 0709 Page 23 SERVICE NOTES...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: