SPECIFICATIONS
Model Number
DvCT36NAT
DvCT36LP
DvCT40NAT
DvCT40LP
Input BTU/Hr maximum (w/ both burners on)
40,000
40,000
47,500
45,000
Input BTU/Hr minimum (w/ both burners on)
26,000
33,000
30,000
35,000
Input BTU/Hr minimum (front burner on only)
11,000
13,000
15,000
16,500
KWH (maximum)
11.72
11.72
13.92
13.19
KWH (minimum)
7.62
9.67
9.38
10.26
orifice - Front
#48
#56
2.25mm
#56
orifice - Rear
2.40mm
1.45mm
2.45mm
1.55mm
Air Shutter opening Front
Full Closed
Full opened
Full Closed
Full opened
Air Shutter opening Rear
Full Closed
Full opened
1/8 Closed
Full opened
Height without standoff (inches)
40-3/4
40-3/4
42-3/4
42-3/4
Width (inches)
45
45
49
49
Depth (inches)
22-1/8
22-1/8
24
24
Gas Inlet Shutoff Valve (pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
NOTE:
Air shutter is at factory-minimum settings. Some vent configurations may require minor air shutter adjustments for optimum performance.
GAS SUPPLY PRESSURES (inches water column)
Gas Type
Maximum
Minimum
Manifold
Natural
14
4.5
3.5
Propane
14
10.8
10
vENTING
LIGHT bULb REPLACEMENT
5 x 8 Direct Vent System
35w Clear Halogen, Bi-Pin 6.35mm base,120vac, UL
ACCESSORIES
The following accessory parts can be obtained from your empire Comfort Systems dealer. For additional information beyond what your dealer
can furnish, contact empire Comfort Systems Inc., 918 Freeburg Ave., Belleville, Illinois 62220-2623.
Model Number
Description
DvCT36
DvCT40
DvP36P...
DvP40P...
A liner is required. Contact your empire Comfort Systems Dealer for available liner.
FBB21
FBB21
Blower, Auto Variable-Speed - Twin
DF36CNB
DF402NB
Beveled Window Frame 1.5-inch, (Brushed Nickel)
DFF36FPD
DFF40FPD
Decorative Front, Forged Iron Frame, Distressed Pewter
DFF36RPD
DFF40RPD
Decorative Arch Insert, Forged Iron, Distressed Pewter
DFF36CPD
DFF40CPD
Decorative Rectangle Insert, Forged Iron, Distressed Pewter (Requires DFF40FPD)
DDF36CPD
DDF40CPD
Decorative Door Set, Forged Iron, Traditional, Distressed Pewter
DCA1ABL
DCA1ABL
Andirons, Black
Model Number
CONvERSION KITS
DvCT36
DvCT40
Description
37506
36884
Conversion Kit, IP System Natural to Propane
37507
36885
Conversion Kit, IP System Propane to Natural Gas
LOG SETS
Model Number
Description
LS36DINF
LS40DINF
Log Set for TruFlame Insert, Ceramic Fiber, Blue Bay - Driftwood
LS36TINF
LS40TINF
Log Set for TruFlame Insert, Ceramic Fiber - Traditional - Charred
* A liner kit and log set must be purchased and installed in order to operate the unit.