background image

 

 

3

 

GAS FRYERS 

 

 

 

 

Kasap Tip Dik Buzdolapları 

 

 
 

 

A1 

PRODUCT DESCRIPTION 

*The Professional Gas Fryers,that  provides high efficiency has been designed to be used in 
industrial kitchens. 
 

Product Code 

Dimensions (mm)   

Weight (kg) 

Packaging 

Dimensions (mm) 

EMP.7FG010 

400x730x850 

63 

480x800x1020 

EMP.7FG020 

800x730x850 

96 

830x800x1020 

 
 

A2 

TECHNICAL INFORMATION 

Product 

Code 

Capacity 

(lt) 

Power 

(KW) 

Gas  Consumption 

(NG) 

Gas  Consumption 

(LPG) 

EMP.7FG010 

18 

10,5 

0,70 

m³/h 

0,52 kg/h 

EMP.7FG020 

2x18 

21 

1,40 

m³/h 

1,05 kg/h 

 
 

A3 

TRANSPORTATION 

*This appliance can not be moved by hand from area to area.It must be moved on pallet with 
forklift  truck. 
 

 

 

 

 

 

 

Summary of Contents for EMP.7FG010

Page 1: ...ECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 3 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G INJECTOR CHANGE AND GAS SETTING Page 9 H GAS CONNECTION IMAGES Page 10 I SPARE PART LIST EXPLODING DRAWING Page 11 ...

Page 2: ...beying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off the appl...

Page 3: ...ght kg Packaging Dimensions mm EMP 7FG010 400x730x850 63 480x800x1020 EMP 7FG020 800x730x850 96 830x800x1020 A2 TECHNICAL INFORMATION Product Code Capacity lt Power KW Gas Consumption NG Gas Consumption LPG EMP 7FG010 18 10 5 0 70 m h 0 52 kg h EMP 7FG020 2x18 21 1 40 m h 1 05 kg h A3 TRANSPORTATION This appliance can not be moved by hand from area to area It must be moved on pallet with forklift ...

Page 4: ...appliance is must have enough ventilation and vent hole The appliance must be connected correctly according to local and national gas standards of your country The appliance gas entrances are indicated with G label on the body Connection to gas fitment must be done with suitable diameter metal flex pipe and spheric valve The spheric valve must be immobilized to a place that is far away from heat a...

Page 5: ...otective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire If there is gas leakage where the appliance is do not fire absolutely and do not use electric Definitely do not allow to check the sealing with flame Level of oil mustn ...

Page 6: ... tank Provide the valve of gas group to be at lighter position Press the button and be sure that pilot group is operated Adjust the appliance s heat 0 8 gradually When the oil temperature reaches indicator temperature heaters are disabled through the agency of limit thermostat When the oil temperature is lower than indicator temperature the limit thermostat steps in and heaters start to work Signa...

Page 7: ...may damage chrome material While cleaning the inside of the fryer take off the basket and filter that are in tank PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person These parts Gas storage pilot thermocouples taps burner lighter and spark plug cable are not maintained so they need to be changed when they have error Check the gas connection hoses in periodic time If th...

Page 8: ... is operated at suitable gas setting or not 2 Check the level of oil THE APPLIANCE STOPPED 1 Gas flow is stopped automatically when the flame is off due to having gas tap that has safety valve In this situation the appliance is not operated 2 When there is gas leakage if there is solenoid gas stopper alarm gas flow is stopped and the appliance is not operated Ventilate the area through the agency ...

Page 9: ...1 6 Change of Burner Injector 1 Rip off the injector at the entrance of burner with a suitable tool 2 Change A injector by paying attention to the datas at chart with suitable injector Image 1 3 Adjust the burner entrance setting F by loosening B bolt and moving the valve to forward back Image 2 4 Change C injector by paying attention to the datas at chart with suitable injector For this it is eno...

Page 10: ...10 GAS FRYERS Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 2 Image 1 Image 3 ...

Page 11: ...11 GAS FRYERS Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP 7FG010 ...

Page 12: ...12 GAS FRYERS Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Page 13: ...13 GAS FRYERS Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP 7FG020 ...

Page 14: ...14 GAS FRYERS Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Reviews: