Fluids Fill/Final Item Checklist/Installation Review Checklist
© 2019 EMP, Inc.
15
Fluids Fill
CAUTION:
Do not use this pump for transferring any fluids other than those for which it was designed;
to do so may damage the pump and will void the warranty.
System fill instructions must be developed, documented, and verified by the system integrator. OEM integrators
must communicate these procedures to the end customer in their maintenance documentation.
Follow these instructions each time the system is drained:
1. Caution must be taken to ensure the system is refilled properly to ensure effective priming of the pump
(For new pumps, pour oil into the pump discharge port to wet the pumping element.).
2. Use care to avoid contaminating oil with debris when working on the system or pump.
Final Item Checklist
•
Are all hoses, fittings, and lines appropriately sized?
•
Are the oil supply and delivery lines to and from the pump securely fastened?
•
Is the pump supplied with the appropriate voltage?
•
Is the pump securely mounted?
•
Are all wires and/or hoses routed away from sharp edges, moving objects, and heat sources?
•
Is the ignition enable on a switched source and not tied to power?
Installation Review Checklist
To determine if the oil pump was successfully installed, reference the Installation Review Checklist for EMP Oil
Pumps, document number 9890094024. This document can be found on the EMP website by searching for the
document number.
!