9970002204
, REV E, 4/16/2012
© 2010 EMP
WP29
Installation Manual
WP29 Electric Water Pump
Part Number
Serial Number(s)
1030002xxx
All
LPE Rev A, 2-May-2013
E2512A
E2512A & WP29
Electric Water Pump
Page 1: ...002204 REV E 4 16 2012 2010 EMP WP29 Installation Manual WP29 Electric Water Pump Part Number Serial Number s 1030002xxx All LPE Rev A 2 May 2013 E2512A Installation Manual E2512A WP29 Electric Water...
Page 2: ...ted periodically While great care is taken in compiling the information contained in this manual EMP cannot assume liability for losses of any nature arising from any errors and or omissions The infor...
Page 3: ...e Locations Bolt Spacing 6 Mounting Screws 7 Material Listing of Major External and Fluid Contacting Parts 7 Operating Range 9 Rated Environmental Conditions 9 Electrical Specifications 10 Parts List...
Page 4: ...he text as follows WARNING THIS SYMBOL IS USED TO MAKE YOU AWARE OF AN UNSAFE CONDITION HAZARD OR PRACTICE THAT CAN RESULT IN PERSONAL INJURY OR DEATH CAUTION THIS SYMBOL IS USED TO ALERT YOU TO A CON...
Page 5: ...4 16 2012 2011 EMP 5 Product Safety Warnings 0 123 4 5 6 2 3 7 8999 979 A block off plug is supplied with this pump for use when this connector is not used traditional on off control wiring configurat...
Page 6: ...Specifications 9970002204 REV E 4 16 2012 2011 EMP 6 Specifications Dimensions Hole Locations Bolt Spacing LPE Rev A 2 May 2013...
Page 7: ...18 8 Stainless Steel 4 1 Volute Cast Aluminum 413 YES 5 1 Impeller Internal 304 Stainless Steel YES 6 1 Shaft 1020 Carbon Steel YES 7 1 Product Label M 714 8 2 Connector Dupont Zytel Nylon 70G33L 7 6...
Page 8: ...to the housing of the pump See below Part Information Location The label containing the part information is located on the outside surface of the pump Label Details Figure 1 Part Label Date Code Seria...
Page 9: ...9 0 4 699 0 4 89 0 4 89 0 Rated Environmental Conditions Table 2 Environmental Conditions Note If Controller Operating Temp exceeds 266f 130c the pump will shut off and stay off until the temperature...
Page 10: ...65826 2 The pump shuts down when the internal controller temperatures reaches 130 C at this point the pump will stop running until the internal controller temperature drops below 125c Once the safe va...
Page 11: ...or WP29 connections 1370001077 DTM Connector 6 Pin Service Parts Kit 1370001078 DTP Connector 4 Pin Service parts Kit Drawings for wiring kits can be found at http www emp corp com support documents a...
Page 12: ...t entry of water or dirt which will result in damage to the pump A block off plug EMP P N 3250001030 can be purchased or one can be fabricated from the Deutsch parts listed in the table Figure 3 On Of...
Page 13: ...EMP Technical Support for detailed information about CAN and Serial implementation and messaging Follow the Schematic in this Manual for proper installation of the wiring kit If installing without the...
Page 14: ...Installation 9970002204 REV E 4 16 2012 2011 EMP 14 Installation Pump Orientation Preferred Orientation View From Front of Pump Acceptable Orientation LPE Rev A 2 May 2013...
Page 15: ...ctions and blockages to prevent cavitation Pump Inlet must be plumbed using 1 0 Dia hose or thin walled tubing Up to 1 length of 0 75 dia is permissible Deviations from this requirement must be approv...
Page 16: ...Troubleshooting 9970002204 REV E 4 16 2012 2011 EMP 16 Troubleshooting 1 1 1 F G 3 1 1 1 1 123 1 123 D 4 123 123 LPE Rev A 2 May 2013...
Page 17: ...WP29 PN 1030002xxx Flow rate vs pump rise 12vdc 0 5 10 15 20 25 30 0 5 10 15 20 25 Pressure psi Flow GPM flow GPM...
Page 18: ......