background image

 

7.0 Using the PAC-3P Leakage Tester 

7.1 Power On PAC-3P Tester 

To turn the PAC-3P on, switch the power button (Figure 1 – No 9) to the ON position. 

NOTE: The LCD screen will light up when unit is on. 
NOTE: If battery is indicated as low, please change or replace with new batteries. 

 

7.2 Preliminary Electrical Safety Check 

Always ensure that the appliance or lead under test is electrically isolated 

 

7.3 Earth Continuity & Leakage Current Measurements 

WARNINGS 

 

For leakage current measurement, the equipment rating to be measured shall NOT exceed: 

 

For 3-phase 20A plug and socket: 415V/20A

 

 

For 3-phase 32A plug and socket: 415V/32A

 

 

7.3.1 Testing 3-Phase APPLIANCES 

Procedure: 

1)  Plug the 3-phase appliance under test into one of the PAC-3P sockets (20A or 32A). 
 

 

 

Summary of Contents for ProTag PAC-3P

Page 1: ...1 ProTagTM PAC 3P 3 Phase Appliance Extension Lead Tester User Manual Made in Australia by Emona Instruments Pty Ltd www emona com au www protag com au...

Page 2: ...User Note 3 4 0 Safety 4 5 0 Accessories 5 6 0 Unit Description 6 7 0 Using the PAC 3P Leakage Tester 8 7 3 1 Testing 3 Phase APPLIANCES 8 7 3 2 Testing 3 Phase EXTENSION LEADS 11 8 0 Recording Resul...

Page 3: ...lt 20A and 32A extension lead test adaptor is included with an earth test pin terminal which eliminates the need for probing of the extension lead earth 2 0 PAC 3P Specifications Display LCD Indicatio...

Page 4: ...ser manual the protection provided by the equipment could be impaired Read this user manual carefully otherwise the use of the instrument may be dangerous for the operator the instrument or for the eq...

Page 5: ...e battery case back into the compartment 5 3 Cleaning Instructions You can clean the instrument regularly or as needed CAUTION Please ensure unit is OFFLINE and disconnected from mains power When the...

Page 6: ...e 1 1 20A Plug to Mains 2 32A Plug to Mains 3 Earth Continuity Clamp 4 20A Test Socket for Appliances Leads 5 32A Test Socket for Appliances Leads 6 9V Battery Compartments 7 LCD Screen 8 GO test key...

Page 7: ...7 6 2 PAC 3P ELA 3 PHASE EXTENSION LEAD TEST ADAPTOR Figure 2 1 20A Plug Test Lead 2 32A Plug Test Lead 3 Earth Test Pin Terminal Attach Earth Clamp Here 1 2 3...

Page 8: ...es 7 2 Preliminary Electrical Safety Check Always ensure that the appliance or lead under test is electrically isolated 7 3 Earth Continuity Leakage Current Measurements WARNINGS For leakage current m...

Page 9: ...will check earth continuity Rpe 1 is a PASS 7 Press SELECT If Rpe PASS it will continue to the next stage of testing If Rpe FAIL the PAC 3P will exit the testing procedure NOTE If the Rpe has failed...

Page 10: ...seconds the measurement will be displayed on screen and indicate whether it is a PASS or FAIL 12 Turn off the 3 Phase mains supply and then safely disconnect the PAC 3P from the 3 Phase mains socket...

Page 11: ...that is easily accessed on the outside of the case so that probing of the 3 phase plug is not required It is designed to prevent the user from probing the earth clamp into the wrong terminal and there...

Page 12: ...p 5 Press the SELECT button until GO LEAD TEST is selected on screen 6 Press GO to proceed 7 Press GO and the tester will conduct the Earth Continuity test 8 Press SELECT If Rpe PASS it will continue...

Page 13: ...appear on screen 11 Press GO to proceed with current leakage measurement After a few seconds the measurement will be displayed on screen and indicate PASS or FAIL 12 Turn off the 3 Phase Mains supply...

Page 14: ...est sequence has been created highlight new test sequence and select Edit Renaming New Test Sequence 8 Press Edit 9 Type in a new name e g 3 Phase Leakage Log Press Enter 10 Hit OK Inserting Sequence...

Page 15: ...te 4 Select the 3 Phase Leakage test sequence that you created 5 Enter in the Site and Location details for the appliance lead 6 Confirm Re Test period is appropriate 7 Press OK to commence the test 8...

Page 16: ...bration For service and calibration please contact EMONA Instruments Pty Ltd 78 Parramatta Rd Camperdown NSW 2050 Tel 02 9519 3933 Fax 02 9550 1278 Email testinst emona com au Web www emona com au www...