EMO Systems E335 Instructions For Use Download Page 1

E.M.O. Systems, Crowther Road, Washington, NE38 0BW, UK. (Tel:+44 (0)191 418 1000), www.emosystems.co.uk

Our Policy is one of continuous development: all specifi cations and design details are subject to change without notice.

EMO MICROPHONE SPLITTERS

INSTRUCTIONS FOR USE

1

CAUTION: UNDER NO CIRCUMSTANCES CONNECT THESE PRODUCTS TO ANY MAINS POWER SUPPLY.

Models 

E325 SINGLE MICROPHONE SPLITTER (20-325)
E335 PANEL MICROPHONE SPLITTER (20-335)
E340 6-WAY RACKMOUNT MICROPHONE SPLITTER (20-340) 

Will pass phantom power to input

Outputs/Connections

XLR type are connectors wired to IEC-268 Part 12 and BS5428 Part 5/3.

Pin 1 – Gnd/Earth/0V
Pin 2 – Signal positive/hot
Pin 3 – Signal negative/cold 

E.M.O. Microphone Splitters provide three microphone level outputs from one microphone level input. Outputs A and B are 
transformer isolated from the input. The Direct Output is connected in parallel with the input XLR.

Phantom Powering

Both the Direct Output and Output A will pass phantom power to the input XLR. To disable this facility on Output A, remove 
the unit from it’s base and cut the link on the track (copper) side of the printed circuit board.

Earth Lift

This switch operates on Output B only. It may be useful in reducing hum problems and solving ground/earth loops in some 
applications.

Phase Reverse

The phase reverse switches may be used, in combination, to correct phase errors in microphones or leads. They can also 
be useful in reducing howlround in on-stage monitoring systems.

Technical Specifi cation

Frequency response: 

20Hz to 20kHz +/- 0.25dB

Input Level: 

Maximum of +4dBu at 30Hz

If Output A or Output B is shorted to ground the maximum level reduction in the other output is 1.5dB.

Note

The E335 panel mounting microphone splitter is suitable for permanent mounting in OEM equipment. Where a multiple 
splitter is required, our E336 19” rack frame will accommodate up to six units (a complete rack is designated E340). This 
frame is also compatible with our direct injection panels. E337 blanking panels should be used for unfi lled space if the rack 
frame is not fully used.

For further information or servicing please contact your local E.M.O. Dealer.