background image

TB-6559

 July 2013 Page 1 of 5

Chargebuster Ion Gun

Installation, Operation and Maintenance

Figure 1.  EMIT Chargebuster Ion Gun

Description

The EMIT Chargebuster Ion Gun is a Point-of-Use 

Ionizer.  It uses compressed air or nitrogen to neutralize 

static charges in localized areas.  Most companies 

address ElectroStatic Attraction, visual imperfections, 

and contamination issues by dislodging charged dust and 

debris with compressed air ionizers.  “There is sometimes 

a need to provide static control in a small defined area or 

location. This may be done to provide static control within 

production equipment, in mini-environments, or to facilitate 

particle removal from part of a product. Ionizers used for 

this purpose may be blow-off guns or nozzles that work 

with a supply of compressed air or nitrogen. They may use 

either nuclear, soft x-ray or any of the previously described 

types of corona ionization technology. It will be important 

to choose a method of ionization and cleanliness of the 

gas supply that is appropriate to the work area.”  (ESD 

handbook ESD TR20.20 section 5.3.6.5.2.4 Point-Of-Use 

Ionization)
The modular and ergonomic design includes an ESD 

protective flexible hose and is easily controlled by 

depressing the trigger.  The EMIT Chargebuster Ion Gun 

meets or exceeds the required limits of ANSI/ESD S20.20 

when tested in accordance with ANSI/ESD S3.1 and ESD 

TR53.
Compact and lightweight, the Chargebuster Ion Gun’s 

console can be mounted anywhere on the workstation for 

easy access.  The console connects to any supply of clean 

dry air or nitrogen, and an internal disposable filter collects 

residual particles, oil and moisture.  The console, gun, and 

air hose are static-dissipative.  The 7 foot hose allows for 

convenient neutralization of localized areas where desired.

© 2013 DESCO INDUSTRIES INC.

Employee Owned

TECHNICAL BULLETIN TB-6559

EMIT

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website: 

DescoEMIT.com

The Chargebuster Ion Gun reduces a static charge of 

±1000 V down to ±100 V in less than one second at a 

distance of six inches (30-psi /0.2MPa inlet pressure).  

Refer to the ESD Association ANSI/ESD Standard STM3.1 

for the test procedure.  The offset voltage (balance) is 

within ±30 V of zero at a distance of six inches, significantly 

less than the required limits of < ±50 volts per ANSI/ESD 

S20.20.
“Necessary non-conductors in the environment cannot 

lose their electrostatic charge by attachment to ground. 

Ionization systems provide neutralization of charges on 

these necessary non-conductive items (circuit board 

materials and some device packages are examples of 

necessary non-conductors). Assessment of the ESD 

hazard created by electrostatic charges on the necessary 

nonconductors in the work place is required to ensure 

that appropriate actions are implemented, commensurate 

with risk to ESDS [ESD sensitive] items”. (ANSI/ESD 

S20.20-2007 Foreword)
“The primary method of static charge control is direct 

connection to ground for conductors, static dissipative 

materials, and personnel. A complete static control program 

must also deal with isolated conductors that cannot be 

grounded, insulating materials (e.g., most common plastics), 

and moving personnel who cannot use wrist or heel straps 

or ESD control flooring and footwear. Air ionization is not 

a replacement for grounding methods. It is one component 

of a complete static control program. Ionizers are used 

when it is not possible to properly ground everything and as 

backup to other static control methods. In clean rooms, air 

ionization may be one of the few methods of static control 

available.” (ESD Handbook TR20.20 Ionization, section 

5.3.6.1)
The Chargebuster Ion Gun is available in two models:

Item

Power Adapter Input

50644

220VAC

50645

120VAC

Packaging

1  Chargebuster Ion Gun with Hose

1  50646 Air Filter

1  24VAC Power Adapter

1  10' Cable

1  Mounting Plate

1  Quick Coupling

1  S-Hook

4  Screws

1  Certificate of Calibration
NOTE: A power cord must be purchased separately for the 

50644 Ion Gun.  Use the 

50545

 power cord for Europe and 

the 

50546 power cord

 for UK/Asia.