26
27
The fixed consumer
gas
supply
outlet should be at
approximately the same height as the cooker
connection point, pointing downwards and
approximately 150mm to the side of the cooker. The
hose should be clear of the floor when the cooker is
in the installed position. Ensure that the safety chain
is installed correctly so that the chain prevents strain
on the hose connections when the cooker is pulled
forward.
If the connection is for natural gas the test point
pressure should be adjusted to 1.00kPa with the wok
burner operating at maximum.
GAS CONNECTION
If installing for use with LPG ensure that an AGA
approved gas regulator suitable for a supply pressure
of 2.75kPa is part of the tank supply and the test point
pressure is adjusted to 2.75kPa.
- There is a connection kit supplied with the cooker.
.
-
It is recommended that an isolating valve and union
be
fitted, to enable simple disconnection for servicing.
These are to be in an accessible location.
-
Check connections are gas tight with soapy water or
other approved method.
- Under no circumstances use a naked flame in
checking for leaks.
-
Check Gas Adjustments (refer
installation - gas
checks and adjustments
).
-
REGULATOR PLACEMENT - We strongly advi
s
e
to locate the Natural Gas regulator close to the
gas inlet and away from the heat of the cooker.
Regulator failure due to heat exposure is not
covered under warranty.
-
When satisfied that the upright cooker is operating
correctly, instruct the customer in its safe operation.
Ensure the customer understands fully by having
them
operate the upright cooker in all its functions.
NA
T GAS
LP
G GAS
Natural Gas
LPG Gas
OR
Gas Flow
Gas Flow
Gas Flow
INSTALLATION - ELECTRICAL CONNECTION
Before connecting the plug into the power socket, follow these instructions:
• The electrical supply for the upright cooker must be a 240 Volt 50 Hz.
• The fuse and electrical wiring of the dwelling must support the load of the appliance.
• The 3-pin plug, used to connect the electricity, must be easily reached when the
upright cooker is in its installed position.
• The upright cooker must be earthed. Connect the upright cooker to a properly
earthed and rated power socket, as appropriate.
• The flexible cord of the upright cooker must not be subject to direct heat and must be
positioned after installation so that its temperature does not exceed 75°C.
IMPORTANT:
If a power socket needs to be installed or relocated, the work must be
done by a licensed electrician.
In New Zealand the cooking range must be connected to the supply by a supply cord
fitted with an appropriately rated plug that is compatible with the socket-outlet fitted to
the final sub-circuit in the fixed wiring that is intended to supply the cooking range.
INSTALLATION - GAS CONNECTION
These technical instructions have been prepared for use by Authorised persons. This
unit
MUST ONLY BE INSTALLED BY AN AUTHORISED PERSON – PROOF IS
REQUIRED FOR WARRANTY SERVICE CLAIMS.
The cooker has been manufactured with Natural Gas injectors fitted. For use with LPG
the cooker must be converted. The conversion kit is supplied. Information on converting
the cooker is included with these instructions.
The requirements of the local gas and electrical authorities must be adhered to,
consult AS5601 as appropriate.
Gas inlet fitting is 1/2” BSP (male) thread.
This appliance can be connected with rigid pipe as specified in AS5601 table 3.1.
This appliance is approved for hose connection in compliance with AS5601, clause
5.12.1.8. The flexible hose must comply with AS/NZS 1869 (AGA Approved), 10mm ID,
class B or D, between 1 – 1.2 m long and in accordance with AS5601 for a high level
connection. The hose should not be subjected to abrasion, kinking or permanent
deformation and should be able to be inspected along its entire length. Unions’
compatible with the hose fittings must be used and all connections tested for gas leaks.