background image

 

CONVERSION TO DIFFERENT TYPES OF GAS 

 

Should the cooktop need to be converted to a gas different to the one it was intended for, the 
injectors must be replaced. 
It there are no spare injectors supplied they can be obtained from Glem Gas Service. 
The injectors are to be installed according to the table on the underside of the cooktop. 
Injectors can be identified by the diameter expressed in hundredths of mm printed on the injector 
itself. 
 

Modify the inlet gas supply as required and fit either the Natural gas regulator or LPG test 
point as appropriate. 

 

Replacing the injectors 

1.  Remove the gas rings and burner caps from the cooktop. 
2.  Using a face spanner, replace injectors “J” (fig. 20) with those specified for the gas to be 

used. 

3. 

Reassemble the burners. 

The burners do not require primary air regulation 

 

Regulating the minimum 

Having replaced the injectors, ignite the burner and remove the control knob. Turn the knob to 
minimum, insert a screw driver and rotate screw to decrease the flame or unscrew it to increase 
the flame. (fig. 20) 

 

The result should be a small constant flame which is even all around the burner crown. 
Finally, check that the flame does not go off when quickly turning the valve from maximum to 
minimum.  On cooktop fitted with flame failure devices, check that the flame slightly brushes the 
thermocouple.  Check correct regulation by leaving the burner on for a few minutes.  If it goes 
off, increase the minimum.   
 
Gas checks and adjustments – Pressure Adjustment 
First shut off the gas to the appliance.  Remove the sealing screw from the regulator test point 
or LPG test point at the rear of the cooker and attach a hose from the mamometer to the point. 
 
Turn the gas back and light the largest burner and smallest burner at the maximum setting.  
Check the pressure and adjust at the regulator if necessary to the settings in the tableor on the 
data plate.  For LPG adjust at the regulator at the cylinder.  Turn the regulator adjusting screw 
clockwise to increase the pressure and anti clockwise to reduce the pressure.  Refit the test 
point sealing screw when finished. 
 

CLEANING 

 

To maintain the cooktop it needs to be cleaned after each use once it has cooled down. 
 Never remove the knobs from their housing to clean the cooktop.
 

 

Enamel parts 

All enamel parts should only be washed with a sponge and soapy water or other specifically 
non-abrasive products. 

Dry completely

 

Stainless Steel 

The  stainless  steel  plate should be cleaned with a damp cloth or with specific stainless steel 
cleaning products. 

Summary of Contents for Glem FC64GWI

Page 1: ...ops Please note This cooktop must be installed by an authorised installer The enclosed installation check list must be completed and signed off by the installer with the installer s Licence number rec...

Page 2: ...2...

Page 3: ...modify the appliance In the case of faults do not attempt repair but ask for assistance from a Glem Gas Service Agent The data plate with its technical data is in a visible position under the housing...

Page 4: ...del number on the data plate MODELS 60cm cooktop with Large burner Emilia SEC64GI FIG 1 1 Medium front burner 2 Medium back burner 3 Small burner 4 Large burner 60cm cooktop with Wok burner 5 Medium f...

Page 5: ...ignition place a flame near to the upper part of the burner press and turn the knob anti clockwise so that it points to the symbol on the panel To turn the burner off turn the knob clockwise until it...

Page 6: ...imum diameter Auxiliary 60 mm with reduction 140 mm Semi rapid 160 mm 200 mm Rapid 200 mm 240 mm Triple crown wok 240 mm 260 mm Dual control 240 mm 260 mm GAS COOKTOP INSTALLATION Installation on the...

Page 7: ...is check the data on the product plate on the cooktop and on this booklet Gas inlet fitting is BSP male thread The gas connection is identified in table figure 7A Fit regulator supplied for natural ga...

Page 8: ...oes not go off when quickly turning the valve from maximum to minimum On cooktop fitted with flame failure devices check that the flame slightly brushes the thermocouple Check correct regulation by le...

Page 9: ...ety valve works properly The electrode and the probe must be cleaned carefully Afterwards replace the burners precisely into their housings To avoid damaging the electric ignition avoid using it when...

Page 10: ...10 DIAGRAMS Fig 1 1 2 4 3 Fig 2 1 2 4 3 Fig 4 Fig 3 Fig 5 Fig 6 1 1 2 2 3 3 4 4 1 2 3 4 5 1 2 3 4 5...

Page 11: ...11 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 7 1 2 3 4 5 Fig 7A...

Page 12: ...12 Fig 14 Fig 16 Fig 17 Fig 19 Fig 15...

Page 13: ...13 Fig 20 Fig 21...

Page 14: ...nation by Glem Appliances P L is found to be defective THIS WARRANTY SHALL NOT APPLY a If the rating plate has been removed or the serial number or other details on it have been removed or rendered il...

Reviews: