background image

 

 
Fixing the cooktop 

The cooktop is to be fixed to the bench as follows: 

1. 

Place the sealing gasket supplied along the outside edge of the hole cut into the bench 
so that the ends of the strips are perfectly joined without overlapping.  

2. 

Position the cooktop into the hole in the bench making sure it is centered. 

3. 

Attach the cooktop to the bench with the supplied mounts as shown in fig. 16. 

4. 

When the sealing gasket is correctly installed, it will protect the cooktop from intrusion of 
liquids. 

 

Connecting the gas

 

The instructions are for a qualified installer. 
The appliance must be installed correctly, conforming to the laws in force. 
Remove the electrical power supply before servicing the appliance. 

 

Gas Inlet Connection Point 

Model SEC64 – 519mm from left hand edge of cut out, 40mm from rear edge. 
Model FC64,SEC75, F74, F75 – 215mm from left hand edge of cut out, 40mm from rear edge 
Model FC95 – 799mm from left hand edge of cut out, 40mm from rear edge  
 
These technical instructions have been prepared  for the use by Authorised persons.  The 
requirements of the local Gas and Electrical authorities must be adhered to, consult 
AG601/AS5601 as appropriate. 
 

 

Before installation, make sure that the gas type (natural gas and LPG) and the 
cooktop are compatible.  To do this, check the data on the product plate on the 
cooktop and on this booklet.

 

 

Gas inlet fitting is ½” BSP (male) thread.

 

 

The gas connection is identified in table figure 7A.

 

 

Fit regulator supplied for natural gas or supplied LPG test point (as applicable)

 

 

It is recommended that an isolating valve and union be fitted, to enable simple 
disconnection for servicing.  These are to be in an accessible location.

 

 

Check connections are gas tight with soapy water or other approved method

 

 
Flexible Hose Connection 

Install with a hose assembly that complies with AS/NZ1869 (AGA Approved). 10mm ID class 
Bor D and in accordance with AS5601.  This hose must not exceed 1.2m in length.  Ensure that 
the hose does not contact the hot surfaces of the cooktop or oven or any other appliance that 
may be installed underneath or adjacent to the cooktop.  The hose must not be subject to contact 
from drawers, abrasion or kinking.  All joints must be checked for leakage using soapy water. 

 

Final Check 

Operate the burners on high and low flames and check that each burner ignites properly and 
has a stable flame.  The following may be abnormal: 

  If the burners have yellow tipping 

  If the pots are sooting underneath 

  If the burners fail to ignite properly 

  If the burners fail to remain alight 

 
When satisfied with the operation of the cooktop please explain to the user the correct method 
of operation.  If the appliance can not be adjusted to operate correctly refer to Glem Gas for 
further assistance. 

 

 

Summary of Contents for Glem FC64GWI

Page 1: ...ops Please note This cooktop must be installed by an authorised installer The enclosed installation check list must be completed and signed off by the installer with the installer s Licence number rec...

Page 2: ...2...

Page 3: ...modify the appliance In the case of faults do not attempt repair but ask for assistance from a Glem Gas Service Agent The data plate with its technical data is in a visible position under the housing...

Page 4: ...del number on the data plate MODELS 60cm cooktop with Large burner Emilia SEC64GI FIG 1 1 Medium front burner 2 Medium back burner 3 Small burner 4 Large burner 60cm cooktop with Wok burner 5 Medium f...

Page 5: ...ignition place a flame near to the upper part of the burner press and turn the knob anti clockwise so that it points to the symbol on the panel To turn the burner off turn the knob clockwise until it...

Page 6: ...imum diameter Auxiliary 60 mm with reduction 140 mm Semi rapid 160 mm 200 mm Rapid 200 mm 240 mm Triple crown wok 240 mm 260 mm Dual control 240 mm 260 mm GAS COOKTOP INSTALLATION Installation on the...

Page 7: ...is check the data on the product plate on the cooktop and on this booklet Gas inlet fitting is BSP male thread The gas connection is identified in table figure 7A Fit regulator supplied for natural ga...

Page 8: ...oes not go off when quickly turning the valve from maximum to minimum On cooktop fitted with flame failure devices check that the flame slightly brushes the thermocouple Check correct regulation by le...

Page 9: ...ety valve works properly The electrode and the probe must be cleaned carefully Afterwards replace the burners precisely into their housings To avoid damaging the electric ignition avoid using it when...

Page 10: ...10 DIAGRAMS Fig 1 1 2 4 3 Fig 2 1 2 4 3 Fig 4 Fig 3 Fig 5 Fig 6 1 1 2 2 3 3 4 4 1 2 3 4 5 1 2 3 4 5...

Page 11: ...11 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 7 1 2 3 4 5 Fig 7A...

Page 12: ...12 Fig 14 Fig 16 Fig 17 Fig 19 Fig 15...

Page 13: ...13 Fig 20 Fig 21...

Page 14: ...nation by Glem Appliances P L is found to be defective THIS WARRANTY SHALL NOT APPLY a If the rating plate has been removed or the serial number or other details on it have been removed or rendered il...

Reviews: