background image

 

 

Before beginning installation, to better handle the hood, we advise removing 

the aluminum filter.  

Before fixing, the outlet exhaust duct for air evacuation to the outside must 

be  installed.  Use  an  outlet  exhaust  duct  with:  -  minimum  indispensable 
length; -Minimum possible bends (maximum angle of bend: 90°); -certified 
material  

(according to local, building & fire 
regulations); and as smooth as possible 
inside. It is also advisable to avoid any drastic 
changes in duct cross-section 
 

(recommended  diameter:  

125mm).   

  

Drill the hole in the wall for the air outlet (133 

mm  diameter)  referring  to  drawings  here  on 
the  right  where  the  measurements  for  the 
various possibilities are indicated.  

  

Decide on the position of the hole for the air 

outlet:  The  hole  must  be  in  the  ceiling, 
according to your requirements, but must be in 
vertical line with your hood. Bear in mind that 
the  hood  can  expel  air  through  the  top  air 
outlet only.  

  

Fitting under wall unit

 

 

1.

 

Before fixing the hood to the wall unit, drill a hole of 130mm diameter 
in the wall unit.   

2.

 

In  any  case,  check  the  position  of  the 
power  outlet  considers  where  the  power 
cable will run, since a hole might have to 
be made in the wall unit to accommodate 
it.   

3.

 

Drill 4 holes in the wall unit,  

 

Reviews: