GLQ252-C, GLQ253-C Installation & Operating Instructions

Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions

P/N: A272-194 Rev 0 6/4/09 Ref: 03361002202

To comply with the published safety standards, the following must be observed when using this 
power supply:

1.  Maximum ambient temperature for the power supply must not exceed 50°C.

2.  When installing the power supply in the end-use equipment, special attention is required 

to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, 
IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage 
distances, clearances, and distance through insulation between primary wiring and earth or 
secondary (SELV) wiring.

3.  The power supply’s rated input voltage is automatically selected. Please refer to the specifi

-

cation sheet for the input voltage range.

4.  The maximum output power of the supply must not exceed the rating indicated in the specifi

-

cation sheet.

5.  The earth ground wire must be connected only to the point marked with the earth ground 

symbol (on the unit).

6.  The disconnection from the line must be in the end system.

7.  Hazardous voltages exist in the primary circuits. Disconnect the power supply before 

servicing.

8.  The unit must be protected by a fuse in the end system. Components, such as capacitors, may 

be positioned in front of the internal fuse.

9.  When operating with a dc input voltage range, the dc source must be rectified from a mains 

supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in 
the end-use installation system.

10. The internal fuse should only be replaced with a F6.3AH, 250 V ac, type 21606.3 manufac-

tured by Littelfuse, type 50CF063H manufactured by Triad, or type S501 manufactured by 
Cooper.

11. This equipment is considered Class I according to protection against electric shock.

12. This power supply is 

 marked following the provisions of the Low Voltage Directive, 

2006/95/EC.

13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an 

e-mail to [email protected]. Please visit our Web site at www.solahd.com for additional 

product information and specification sheets.

Output Ratings

Model

Output Voltage (V)

30 CFM Forced Air Cooling 

(unit not convection rated)

Max. Output Current (A)

Max. Output Power (W)

GLQ252-C

+5

35.0

250 with cover

+12

10.0

-12

6.0

+5 to +25

6.0

GLQ253-C

+5

35.0

+15

10.0

-15

6.0

+5 to +25

6.0

Mechanical Outline

L14

C37

C38

C36

SK3

R9

C35

R10

R76

R75

L4

SK4

SK5

B

C42

1

2

L6

B

L

N

A

A

L

N

SK7

R13

R26

R32

L11

L10

L16

SK1

SK2

B

B

B

6

5

4

3

2

1

1

2

1

8

4th O/P Adj.

O/P Adj.

A

B

Bus Bar

3

2

1

Connector PIN Designation

Input Connector

PIN

GLQ252-C

GLQ253-C

SK1

1

Neutral

2

Line

3

Earth GND

Output Connector

PIN

GLQ252-C

GLQ253-C

Bus Bar

A

+5 V

B

Common

SK2

1

+12 V

+15 V

2, 3

Common

4

-12 V

-15 V

5

Return (float)

6

+5 V to +25 V adj. (float)

SK3

1

+Sense

2

-Sense

3

Inhibit (normally open)

4

Inhibit (normally closed)

5

Common

6

Active current share

7

P OK

8

Dc OK

SK4

1

Fan (+)

2

Fan (-)

SK5

1

+5 V (aux)

2

Common

SK7

1

Fan (+)

2

Fan (-)