Emerson SNUGGER CF804SBS02 Owner'S Manual Download Page 8

8

  

U.L. Model No.: 52-CL

6. Using Your Ceiling Fan

CHAIN COUPLING

3-SPEED SWITCH 

PULL CHAIN

WOOD PENDANT 

WITH CHAIN

  Figure 11

To reduce the risk of fire or electrical shock, do NOT 

use this fan with any solid-state speed control device.

 

WARNING

!

Do not use water when cleaning your ceiling fan. 

It could damage the motor or the blades and create the 

possibility of an electrical shock.

 

WARNING

!

IMPORTANT CARE INSTRUCTIONS 

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only 

maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to 

avoid scratching the finish.
Abrasive cleaning agents are not required and should 

be avoided to prevent damage to finish.

7. Maintenance

Reverse Switch Information

Season 

Blade Rotation Direction

Summer  

Counter-Clockwise

Winter Clockwise

6.1

Restore Electrical Power to the Outlet Box by turning 

the Electricity on at the Main Fuse Box.
Connect the Wood Pendant with Chain to the 3-Speed 

Switch Pull Chain using the Chain Coupling (Figure 11).
Check the operation of the Fan by gently pulling 

on the 3-Speed Switch Pull Chain (Figure 11). 

The operation sequence is as follows:
  1st pull - High
  2nd pull - Medium

3rd pull - Low
4th pull - OFF

REVERSE 

SWITCH

SWITCH 

HOUSING

6.2

During Summer Months, run the Fan Counter-

Clockwise, as you look up at it, to direct airflow 

downward.
During the Winter Months, run the Fan Clockwise, as 

you look up at it, to direct airflow upward.
If airflow is desired in the opposite direction, turn the 

Ceiling Fan OFF and wait for the Blades to stop turning.
Slide the Reverse Switch (located on the Switch 

Housing) to the opposite position, and turn the Ceiling 

Fan on again (Figure 12).
The Fan Blades will turn in the opposite direction and 

reverse the airflow.

  Figure 12

Summary of Contents for SNUGGER CF804SBS02

Page 1: ...3 9 Lbs Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com TRADITIONAL CF805SBS02 Brushed Steel CF805SORB02 Oil Rubbed Bronze CF805SWW02 Appliance White 42 Model Numbers Net Weight 11 2 Lbs CF804SBS02 Brushed Steel CF804SORB02 Oil Rubbed Bronze CF804SWW02 Appliance White ...

Page 2: ...recaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7kg 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly u...

Page 3: ...OTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding 2 6 3 4 5 7 8 1 HARDWARE CONTENTS Part Description Quantity 1 Wire Connectors 12 ga 3 2 M5 x 6mm Phillips Washer Head Screws 16 3 M5 x 10mm Phillips Pan Head Screws with Internal Tooth Washers 5 4 1 4 Hex Locknuts 4 5 W...

Page 4: ... Circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is no...

Page 5: ...ified electrician if in doubt WARNING To reduce the risk of injury install the fan so that the blades are at least 7 ft 2 1m above the floor Figure 1 CAUTION MOUNTING PLATE LEVELING WASHERS if required OUTLET BOX MOUNTING SCREWS 2 supplied with outlet box Figure 2 3 1 Securely attach the Mounting Plate to the Outlet Box Figure 2 using Two Screws supplied with outlet box NOTE For better fan perform...

Page 6: ...igure 4 To avoid risk of fire or shock check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 4 2 Connect the Fan Motor White Wire to the Supply White neutral Wire using a supplied Wire Connector Figure 5 WIRE CONNECTOR FAN ...

Page 7: ...pinch wires between the motor bracket and mounting plate WARNING M5 x 10mm PHILLIPS PAN HEAD SCREWS WITH INTERNAL WASHERS 4 FAN HOUSING HOLES 4 5 2 Align the Four Holes in the Fan Housing with the Holes in the Mounting Plate and install Four M5 x 10mm Phillips Pan Head Screws with Internal Tooth Washers supplied Figure 8 M5 x 6mm PHILLIPS WASHER HEAD SCREWS 3 per blade BLADES 5 FLANGES 5 CAPTIVE S...

Page 8: ...r Counter Clockwise Winter Clockwise 6 1 Restore Electrical Power to the Outlet Box by turning the Electricity on at the Main Fuse Box Connect the Wood Pendant with Chain to the 3 Speed Switch Pull Chain using the Chain Coupling Figure 11 Check the operation of the Fan by gently pulling on the 3 Speed Switch Pull Chain Figure 11 The operation sequence is as follows 1st pull High 2nd pull Medium 3r...

Page 9: ...ake sure all screws in motor housing are snug not over tight 3 Screws securing fan blade flanges 3 Check to make sure the screws which attach the fan to motor are loose blade flanges to the motor are tight 4 Wire connectors inside switch housing 4 Check to make sure wire connectors in switch housing rattling are not rattling against each other or against the interior wall of the switch housing 5 S...

Page 10: ...nge Sets set of 5 762573 3 762573 6 762573 3 Blade Sets set of 5 765172 DC MH 765172 DC MO 765172 WW BO 4 Loose Parts Bag Containing 762567 3 762567 1 762567 2 Blade Hardware Hanging Hardware Pull Chain Ball 5 Harness Wiring 762569 3 762569 2 762569 4 Owner s Manual BP7192 10 BP7192 10 BP7192 10 42 Part Numbers Key Model Number Model Number Model Number No Description CF804SBS02 CF804SORB02 CF804S...

Page 11: ...normal wear and tear rather than due to defects in materials or workmanship Loss or damage resulting from conditions beyond our reasonable control including without limitation unforeseeable operating environmental conditions repairs not made at Our factory or authorized service center use of parts or accessories not provided to You as part of this warranty by Our factory or authorized service cent...

Page 12: ...can be found on the nameplate on top of the fan housing The date code can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above and keep it in a safe place for future use Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday DIVISION OF LUMINANCE BRANDS 1945 S Tubeway A...

Reviews: