Specifications
52
7.2
Environmental Specifications
7.2.1
Ambient Temperatures and Humidity
Ambient temperatures and humidity values for the RXi2-XP IPC are provided in the following
table.
Table 7-3
Temperature Specifications
Item
Level A
Temperature
Storage
-40 to 85°C (-40 to 185 °F)
Operating
-40 to 60°C (-40 to 140 °F)
Humidity
Operating
5 to 95% rH, non-condensing, at 40°C (104 °F)
Storage
7.2.2
Shock and Vibration without 2.5 inch Mass Storage
The RXi2-XP IPC without 2.5 inch mass storage options is designed to meet the shock and
vibration values listed in the following table.
Table 7-4
Shock and Vibration Specifications without Additional 2.5 inch Mass Storage
Item
Vita 47 V1
Vibration
Spectrum
5 to 100 Hz
Acceleration
2 g RMS
Shock
Half sine or sawtooth
20 g
Duration
11 ms
7.2.3
Shock and Vibration with 2.5 inch Mass Storage
Due to additional interchangeable non-rugged mechanical parts, Emerson does not recommend
exposing the system to shock and vibration.
7.2.4
Altitude
Altitude, air pressure, and ambient temperature influence the thermal operation of the
components described in this document. They have been developed and tested at ~500 m (1650
ft) above sea level at a typical ambient temperature of 20°C (68 °F). Because of only marginal
variations within a limited range of altitudes, this product operates as specified within altitudes
from sea level to 1,000 m (6,560 ft), depending on the level. This is with reference to
temperature ranges of air-cooled versions.
Note:
Emerson can assist the user in planning operation outside this altitude range upon request.