Thermal Performance
32
8.1.3
Temperature Monitoring and Protection
The RXi2-BP can monitor critical temperatures on-module and on-carrier and is configured to protect
itself from an overtemperature condition.
IPC peripheral circuitry provides two static thermal zones (TZE1 and TZE2) and the CPU circuitry
provides also two thermal zones (TZCP and TZD1).
The current thermal state can be always checked with the THRM LED? state.
If an overtemperature situation is present and the system shuts off, the last LED state is visible also in
S4/S5.
The following activities are implemented when conducted in an ACPI aware Operating System. Any
non-ACPI aware operating system must rely on internal hardware protection and must be evaluated
separately on a case-by-case basis.
Once the T
HOT
threshold is exceeded, the system will try to shutdown graceful into S4, depending on OS
configuration.
Figure 26: Thermal Zones: Tactive to Thot
Temp
SMB-Alert
LED Red
Thot
OS
SMBus
Exp
TZ: Active
Tactive
Note: Thermal Zone
‘
Active
’
is optional and not implemented in fanless RXi2-BP design.