Commissioning
July 2016
Commissioning
Note
The Rosemount 648 Wireless and all other wireless devices should be installed only after the
Smart Wireless Gateway has been installed and is functioning properly. Wireless devices
should also be powered up in order of proximity from the Smart Wireless Gateway,
beginning with the closest device to the Gateway. This will result in a simpler and faster
network installation.
4.3
Verify operation
The transmitter can be commissioned before or after installation. It may be useful to
commission it on the bench, before installation, to ensure proper operation and to become
familiar with its functionality. When applicable, make sure the instruments are installed in
accordance with intrinsically safe or non-incendive field wiring practices. The device will be
powered whenever the power module is installed. To avoid depleting the power module,
make sure it is removed when the device is not in use.
Operation can be verified in four locations: at the device via the LCD display, using a Field
Communicator, the Smart Wireless Gateway's integrated web interface, or using AMS
™
Suite Wireless Communicator or AMS Device Manager.
4.3.1
LCD display
During normal operation, the LCD display will display the PV value at the wireless transmit
rate up to as fast as one minute intervals. Refer to
“LCD display screen messages” on
for error codes and other LCD display messages. Press the
Diagnostic
button to
display the TAG, Device ID, Network ID, Network Join Status and Device Status screens. For
Device Status screens, see
“LCD display screen messages” on page 43
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that
may cause undesired operation.
This device must be installed to ensure a minimum antenna separation distance of
20 cm from all persons.
The power module may be replaced in a hazardous area. The power module has surface
resistivity greater than one gigaohm and must be properly installed in the wireless
device enclosure. Care must be taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
Summary of Contents for Rosemount X-well 648
Page 2: ......
Page 6: ...vi Reference Manual 00809 0200 4648 Rev BB Title Page July 2016 Title Page ...
Page 10: ...4 Reference Manual 00809 0200 4648 Rev BB Contents July 2016 Contents ...
Page 12: ...2 Reference Manual 00809 0200 4648 Rev BB Introduction July 2016 Introduction ...
Page 36: ...26 Reference Manual 00809 0200 4648 Rev BB Configuration July 2016 Configuration ...
Page 52: ...42 Reference Manual 00809 0200 4648 Rev BB Commissioning July 2016 Commissioning ...
Page 66: ...56 Reference Manual 00809 0200 4648 Rev BB Troubleshooting July 2016 Troubleshooting ...
Page 89: ......