B.2.2
Electrical input protection
The input circuit is protected against voltage-reversed polarity, voltage transients, surges,
and spikes according to EN50270.
B.3
Mechanical specifications
Enclosure
The detector, source, and tilt mount are stainless steel, 316 electro chemical, and
passivized coating.
Explosion proof
ATEX, IECEx, and UK CA
Ex II 2(2) G D
Ex db eb ib [ib Gb] IIB+H2 T4 Gb
Ex tb [ib Db] IIIC T135 °C Db
Water and dust tight
IP66 and IP68
NEMA
®
250 Type 6p
Electrical modules
Conformal coated
Electrical connection
Two options, specified at time of order:
•
2 x M25 for International Organization on Standardization (ISO)
•
2 x
¼
-in-14 NPT conduits
Dimensions
•
Detector: 10.5 in (267 mm) x 5.1 in (130 mm) x 5.1 in (130 mm)
•
Source: 10.5 in (267 mm) x 5.1 in (130 mm) x 5.1 in (130 mm)
•
Tilt mount: 4.7 in (119 mm) x 4.7 in (119 mm) x 5.5 in (140 mm)
Weight
Detector: 11 lb (5 kg)
Source: 11 lb (5 kg)
Tilt mount: 4.2 lb (1.9 kg)
Reference Manual
Specifications
00809-0100-4035
May 2022
Rosemount 935
59
Summary of Contents for Rosemount 935
Page 8: ...Product overview Reference Manual May 2022 00809 0100 4035 8 Emerson com Rosemount ...
Page 16: ...Technical description Reference Manual May 2022 00809 0100 4035 16 Emerson com Rosemount ...
Page 22: ...Operating modes Reference Manual May 2022 00809 0100 4035 22 Emerson com Rosemount ...
Page 46: ...Operation Reference Manual May 2022 00809 0100 4035 46 Emerson com Rosemount ...
Page 52: ...Troubleshooting Reference Manual May 2022 00809 0100 4035 52 Emerson com Rosemount ...
Page 56: ...Ordering information Reference Manual May 2022 00809 0100 4035 56 Emerson com Rosemount ...
Page 62: ...Specifications Reference Manual May 2022 00809 0100 4035 62 Emerson com Rosemount ...
Page 70: ...Wiring configurations Reference Manual May 2022 00809 0100 4035 70 Emerson com Rosemount ...
Page 74: ...Support Reference Manual May 2022 00809 0100 4035 74 Emerson com Rosemount ...