7.4
Detector is in constant Misalignment mode
Host status = M
0-20 = 2.5 mA
Light emitting diode (LED) = yellow, blinking
Table 7-4: Potential Causes and Resolutions
Potential cause
Resolution
Poor alignment
Align.
Detector fault
Replace or repair the detector.
7.5
Detector at V fault
Host status = V
0-20 = 1 mA
Light-emitting diode (LED) = yellow, blinking
Table 7-5: Potential Causes and Resolutions
Potential cause
Resolution
Low/high input voltage
Check the power supply and installation.
Detector fault
Replace or repair the detector.
7.6
Internal fault
Host status = F
0-20 = 1 mA
Light-emitting diode (LED) = yellow, blinking
Table 7-6: Potential Cause and Resolution
Potential cause
Resolution
Internal fault
Replace the detector.
Troubleshooting
Reference Manual
May 2022
00809-0100-4035
50
Emerson.com/Rosemount
Summary of Contents for Rosemount 935
Page 8: ...Product overview Reference Manual May 2022 00809 0100 4035 8 Emerson com Rosemount ...
Page 16: ...Technical description Reference Manual May 2022 00809 0100 4035 16 Emerson com Rosemount ...
Page 22: ...Operating modes Reference Manual May 2022 00809 0100 4035 22 Emerson com Rosemount ...
Page 46: ...Operation Reference Manual May 2022 00809 0100 4035 46 Emerson com Rosemount ...
Page 52: ...Troubleshooting Reference Manual May 2022 00809 0100 4035 52 Emerson com Rosemount ...
Page 56: ...Ordering information Reference Manual May 2022 00809 0100 4035 56 Emerson com Rosemount ...
Page 62: ...Specifications Reference Manual May 2022 00809 0100 4035 62 Emerson com Rosemount ...
Page 70: ...Wiring configurations Reference Manual May 2022 00809 0100 4035 70 Emerson com Rosemount ...
Page 74: ...Support Reference Manual May 2022 00809 0100 4035 74 Emerson com Rosemount ...