7
Troubleshooting
7.1
Maintenance call
Reference and Signal are below 2 Vdc at gain 9.
Light-emitting diode (LED) = green, blinking, 1 Hz
Table 7-1: Potential causes and resolutions
Potential cause
Resolution
Poor alignment
Align.
Dirt on the window
Clean the window.
Poor light source
Replace the light source.
Detector fault
Replace or repair the detector.
7.2
Detector is in constant Obscuration mode
Host status = O or I
0-20 = 2 mA
Light emitting diode (LED) = yellow, blinking
Table 7-2: Potential Causes and Resolutions
Potential cause
Resolution
Poor alignment
Align.
Dirt on the window
Clean the window.
Poor light source
Replace the light source.
Detector fault
Replace or repair the detector.
7.3
Detector is in constant Saturation mode
Host status = S
0-20 = 2 mA
Light emitting diode (LED) = yellow, blinking
Table 7-3: Potential Causes and Resolutions
Potential cause
Resolution
Installation distance is lower than allowed
Use a different model.
Detector fault
Replace or repair the detector.
Reference Manual
Troubleshooting
00809-0100-4035
May 2022
Rosemount 935
49
Summary of Contents for Rosemount 935
Page 8: ...Product overview Reference Manual May 2022 00809 0100 4035 8 Emerson com Rosemount ...
Page 16: ...Technical description Reference Manual May 2022 00809 0100 4035 16 Emerson com Rosemount ...
Page 22: ...Operating modes Reference Manual May 2022 00809 0100 4035 22 Emerson com Rosemount ...
Page 46: ...Operation Reference Manual May 2022 00809 0100 4035 46 Emerson com Rosemount ...
Page 52: ...Troubleshooting Reference Manual May 2022 00809 0100 4035 52 Emerson com Rosemount ...
Page 56: ...Ordering information Reference Manual May 2022 00809 0100 4035 56 Emerson com Rosemount ...
Page 62: ...Specifications Reference Manual May 2022 00809 0100 4035 62 Emerson com Rosemount ...
Page 70: ...Wiring configurations Reference Manual May 2022 00809 0100 4035 70 Emerson com Rosemount ...
Page 74: ...Support Reference Manual May 2022 00809 0100 4035 74 Emerson com Rosemount ...