158
Reference Manual
00809-0300-4750, Rev CA
March 2016
9.3
Installation check and guide
Use this guide to check new installations of Rosemount magnetic flowmeter systems that
appear to malfunction.
9.3.1
Transmitter
Before applying power to the magnetic flowmeter system, perform the following
transmitter checks:
1.
Record the transmitter model number and serial number.
2.
Visually inspect the transmitter for any damage including the terminal block.
3.
Verify the proper wiring connections have been made for the power and outputs.
Apply power to the magnetic flowmeter system before making the following transmitter
checks:
1.
Check for an active error message or status alert. Refer to
2.
Verify the correct sensor calibration number is entered in the transmitter. The
calibration number is listed on the sensor nameplate.
3.
Verify the correct sensor line size is entered in the transmitter. The line size value is
listed on the sensor nameplate.
4.
Verify the analog range of the transmitter matches the analog range in the control
system.
5.
Verify the forced analog output and forced pulse output of the transmitter
produces the correct output at the control system.
6.
If desired, use a Rosemount 8714D to verify the transmitter calibration.
9.3.2
Sensor
Be sure that power to magnetic flowmeter system is removed before beginning the
following sensor checks:
1.
Record the sensor model number and serial number.
2.
Visually inspect the sensor for any damage including inside the remote junction
box, if applicable.
3.
For horizontal flow installations, ensure the electrodes remain covered by process
fluid. For vertical or inclined installations, ensure the process fluid is flowing up into
the sensor to keep the electrodes covered by process fluid.
4.
Verify the flow arrow is pointing in the same direction as forward flow.
5.
Ensure the grounding straps on the sensor are connected to grounding rings or the
adjacent pipe flanges. Improper grounding will cause erratic operation of the
system. Sensors with a ground electrode will not require the grounding straps to
be connected.
Summary of Contents for Rosemount 8750W
Page 2: ......
Page 96: ...84 Reference Manual 00809 0300 4750 Rev CA Operation March 2016 Operation ...
Page 168: ...156 Reference Manual 00809 0300 4750 Rev CA Maintenance March 2016 Maintenance ...
Page 214: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 202 Wiring Diagrams ...
Page 218: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 206 Wiring Diagrams ...
Page 219: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 207 Wiring Diagrams ...
Page 220: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 208 Wiring Diagrams ...
Page 222: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 210 Wiring Diagrams ...
Page 223: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 211 Wiring Diagrams ...
Page 224: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 212 Wiring Diagrams ...
Page 225: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 213 Wiring Diagrams ...
Page 227: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 215 Wiring Diagrams ...
Page 228: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 216 Wiring Diagrams ...
Page 229: ...Wiring Diagrams March 2016 Reference Manual 00809 0300 4750 Rev CA 217 Wiring Diagrams ...
Page 263: ......