![Emerson Rosemount 644 with HART Protocol Reference Manual Download Page 29](http://html.mh-extra.com/html/emerson/rosemount-644-with-hart-protocol/rosemount-644-with-hart-protocol_reference-manual_104732029.webp)
21
Reference Manual
00809-0200-4728, Rev SA
Configuration
July 2018
Configuration
2.8
Configure device outputs
2.8.1
Re-range the transmitter
Re-ranging the transmitter sets the measurement range to the limits of the expected readings for a
certain application. Setting the measurement range to the limits of expected readings maximizes
transmitter performance; the transmitter is most accurate when operated within the expected
temperature range for the application.
The range of expected readings is defined by the Lower Range Value (LRV) and Upper Range Value (URV).
The transmitter range values can be reset as often as necessary to reflect changing process conditions.
For a complete listing of Range and Sensor limits.
Note
The re-range functions should not be confused with the trim functions. Although the re-range function
matches a sensor input to a 4–20 mA output, as in conventional calibration, it does not affect the
transmitter’s interpretation of the input.
Select from one of the methods below to re-range the transmitter.
Field Communicator
From the
HOME
screen, enter the Fast Key sequence.
AMS Device Manager
1. Right click on the device and select
Configure
.
2. In the left navigation pane select
Manual Setup
.
3. On the
Analog Output Tab
find the Primary Variable Configuration group box.
4. Change the
Upper Range Value
and
Lower Range Value
to their desired settings.
5. Select
Apply
when complete.
LOI
Reference the image below to find the range value configuration path on the LOI.
Figure 2-13. Re-ranging the Transmitter with LOI
Lower range value Upper range value
Device Dashboard Fast Keys
2, 2, 5, 5, 3
2, 2, 5, 5, 2
ENTER VALUES
ENTER VALUES
BACK TO MENU
EXIT MENU
LRV
LRV
URV
URV
BACK TO MENU
EXIT MENU
VIEW CONFIG
SENSOR CONFIG
UNITS
RERANGE
RERANGE
LOOP TEST
DISPLAY
EXTENDED MENU
EXIT MENU
Summary of Contents for Rosemount 644 with HART Protocol
Page 2: ......
Page 8: ...vi Reference Manual 00809 0200 4728 Rev SA Title Page July 2018 Title Page ...
Page 48: ...40 Reference Manual 00809 0200 4728 Rev SA Configuration July 2018 Configuration ...
Page 62: ...54 Reference Manual 00809 0200 4728 Rev SA Installation July 2018 Installation ...
Page 111: ......