![Emerson Rosemount 644 HART Reference Manual Download Page 45](http://html.mh-extra.com/html/emerson/rosemount-644-hart/rosemount-644-hart_reference-manual_104731045.webp)
35
Reference Manual
00809-0100-4728, Rev MB
Configuration
July 2016
Configuration
2.11
Diagnostics and service
2.11.1
Performing a loop test
The Analog
Loop Test
verifies the output of the transmitter, the integrity of the loop, and the operations
of any recorders or similar devices installed in the loop. To initiate a loop test, follow the steps below.
The host system may provide a current measurement for the 4-20 mA HART output. If not, connect a
reference meter to the transmitter by either connecting the meter to the test terminals on the terminal
block, or shunting transmitter power through the meter at some point in the loop.
Using a Field Communicator
Using AMS Device Manager
1. Right click on the device and select
Service Tools
.
2. In the left navigation pane choose
Simulate
.
3. On the
Simulate
Tab find the
Perform Loop Test
button in the
Analog Output Verification
group
box.
4. Follow the guided instructions and click
Apply
when complete.
Using Local Operator Interface
Reference the figure below to find the path to the Loop Test in the LOI menu.
Figure 2-20. Configuring the Tag with LOI
2.11.2
Simulate digital signal (Digital Loop Test)
The
Simulate Digital Signal
function adds to the analog loop test by confirming the HART output values
are outputting correctly. Digital Loop Test is only available in HART Revision 7 mode.
Using a Field Communicator
From the
HOME
screen, enter the Fast Key sequence
Device Dashboard Fast Keys
3, 5, 1
From the
HOME
screen, enter the Fast Key sequence
Device Dashboard Fast Keys
3, 5, 2
SET 4 MA
SET 20 MA
SET CUSTOM
END LOOP TEST
BACK TO MENU
EXIT MENU
VIEW CONFIG
SENSOR CONFIG
UNITS
RERANGE
LOOP TEST
LOOP TEST
DISPLAY
EXTENDED MENU
EXIT MENU
Summary of Contents for Rosemount 644 HART
Page 2: ......
Page 16: ...6 Reference Manual 00809 0100 4728 Rev MB Introduction July 2016 Introduction ...
Page 86: ...76 Reference Manual 00809 0100 4728 Rev MB Troubleshooting July 2016 Troubleshooting ...
Page 138: ...128 Reference Manual 00809 0100 4728 Rev MB Index July 2016 Index ...
Page 139: ......