Table C-18: Advanced Configuration Transducer Block Parameters
(continued)
Index
Number
Parameter
Description
50
ECHO_DISTANCE
Distance to found echo.
51
ECHO_AMPLITUDE
Signal Amplitude of found echo.
52
ECHO_CLASS
Classification of found echo, see
.
53
ECHO_FALSE
Distance to registered false echo
54
ATP_DISTANCE
You can filter out weak disturbing echoes by
creating a noise threshold table defined by ATP
Distance and ATP Threshold points.
55
ATP_THRESHOLD
Amplitude threshold. See ATP_DISTANCE.
Table C-19: Echo Classification
VALUE
Description
0
Unknown
1
Irrelevant
2
Surface
3
False echo
4
Double Bounce
5
Secondary Surface
6
Tank Bottom Echo
7
Beam below surface
8
Beam above surface
9
LPG pin
Table C-20: Echo Update
VALUE
Description
0
Uninitialized
1
Normal operation
2
Read a snapshot of found echoes
Table C-21: Echo Command
VALUE
Description
0
Uninitialized
1
Add false echo
2
Remove false echo
F
OUNDATION
™
Fieldbus Block Information
Reference Manual
September 2019
00809-0100-5900
292
Reference Manual
Summary of Contents for Rosemount 5900S Series
Page 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Page 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Page 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Page 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...