Figure 4-4: The Tank Scan Window
When the
Tank Scan
window is opened, the system starts reading tank data from
the gauge (indicated by a progress bar in the lower right-hand corner).
Tank scan window
The
Tank Scan
window contains the Graph Area, Legend/Options area, File Storage
buttons, and various action buttons.
The Tank Echo curve shows the measurement signal in graphical form. In addition to the
surface echo there might be echoes from obstacles in the tank.
In the graph area you can configure the gauge to filter out echoes that originate from
obstacles in the tank in order to facilitate tracking of the product surface echo.
The tank echo and echo peaks can be refreshed at any time with the
Reread From Gauge
button. The new echo curve will be shown as a black line and the previous curve as a grey
line. The graph may show up to two old echo curves. An old echo peak will be marked by a
small cross. This can be used to compare the existing tank signal with previous signals.
See the Rosemount Tank Gauging
how to use the Tank Scan function.
4.4.3
Empty tank handling
The Empty Tank Handling function handles situations when the surface echo is close to the
tank bottom. It has the ability to:
•
track weak product echoes
•
handle lost echoes
If the surface echo is lost this function makes the Rosemount 5900S present a zero-level
measurement.
Configuration
Reference Manual
September 2019
00809-0100-5900
106
Reference Manual
Summary of Contents for Rosemount 5900S Series
Page 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Page 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Page 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Page 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...