Reference Manual
00809-0100-4024, Rev CA
Configuration
March 2020
63
Configuration
Section 4
Configuration
Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 64
Tank geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 66
Analog output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 68
Process conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70
Temperature measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70
Volume calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 71
Advanced functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 71
4.1
Safety messages
Procedures and instructions in this section may require special precautions to ensure the safety of the
personnel performing the operations. Information that raises potential safety issues is indicated by a
warning symbol ( ). Please refer to the following safety messages before performing an operation
preceded by this symbol.
4.2
Overview
To be able to fully utilize the Rosemount 5600 Radar Level transmitter it has to be properly configured. To
configure the transmitter access the configuration parameters and assign them appropriate values. In
this section you will find the parameters used and how they affect your application. The preferred user
interface for the configuration is the Rosemount Radar Master software. See
. Configuration can also be performed using the:
AMS / 375 Field Communicator (see
DeltaV
Or others
Limited support for various configuration parameters may apply when using certain configuration tools.
Explosions could result in death or serious injury:
Verify that the operating environment of the transmitter is consistent with the appropriate hazardous
locations certifications.
Before connecting a HART-based communicator in an explosive atmosphere, make sure the
instruments in the loop are installed in accordance with intrinsically safe or non-incendive field wiring
practices.
Do not remove the transmitter cover in explosive atmospheres when the circuit is alive.
Summary of Contents for Rosemount 5600 Series
Page 2: ......
Page 4: ...4 Reference Manual 00809 0100 4024 Rev CA Title Page March 2020 Title Page ...
Page 16: ...16 Reference Manual 00809 0100 4024 Rev CA Introduction March 2020 Introduction ...
Page 125: ...125 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index Strapping Table 71 ...
Page 126: ...126 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index ...
Page 127: ......