Upper null zone
The Upper Null Zone defines how close to the transmitter's reference point a level value is
accepted. You can extend this value to block out disturbing echoes close to the antenna,
for example from the tank nozzle or bypass well inlet.
Note
Make sure the 20 mA value is below the Upper Null Zone. Measurements are not
performed within the Upper Null Zone (UNZ).
Related information
C.3.6
Advanced
Calibration offset
Difference between surface distance measured by transmitter and the same distance
measured by, for example, hand-dipping with a measurement tape. A positive Calibration
Offset value will increase the presented level value.
It is recommended to run the Verify Level tool to match the product level reported by the
transmitter to a reference measurement.
Related information
User defined variable setup
This section applies only to transmitters ordered with Smart Diagnostics Suite (option
code DA1).
Name
Name of the user defined variable. It is recommended to enter a short name to fit into the
LCD display area.
Input register
Enter the number of the input register that contains value of the user defined variable. See
for a list of suitable input registers.
The default value is 20210 (Distance).
Configuration parameters
Reference Manual
February 2020
00809-0100-4408
266
Reference Manual
Summary of Contents for Rosemount 5408
Page 4: ...4 ...
Page 8: ...Contents Reference Manual February 2020 00809 0100 4408 viii Reference Manual ...
Page 10: ...Introduction Reference Manual February 2020 00809 0100 4408 10 Reference Manual ...
Page 20: ...Transmitter overview Reference Manual February 2020 00809 0100 4408 20 Reference Manual ...
Page 72: ...Mechanical installation Reference Manual February 2020 00809 0100 4408 72 Reference Manual ...
Page 100: ...Operation Reference Manual February 2020 00809 0100 4408 100 Reference Manual ...
Page 240: ...Product certifications Reference Manual February 2020 00809 0100 4408 240 Reference Manual ...
Page 242: ...Product certifications Reference Manual February 2020 00809 0100 4408 242 Reference Manual ...
Page 244: ...Product certifications Reference Manual February 2020 00809 0100 4408 244 Reference Manual ...
Page 246: ...Product certifications Reference Manual February 2020 00809 0100 4408 246 Reference Manual ...
Page 248: ...Product certifications Reference Manual February 2020 00809 0100 4408 248 Reference Manual ...