Reference Manual
00809-0100-4882, Rev AB
May 2019
Rosemount 5081FG
1-9
Table 1-1. Product Matrix
5081FG High Temperature Oxygen Flue Gas Analyzer
Code
Sensing Probe Type
1
20 in. (508 mm) probe, 1/4 in. tube fittings
2
26 in. (660 mm) probe, 1/4 in. tube fittings
3
38 in. (965 mm) probe, 1/4 in. tube fittings
Code
Probe Outer Tube Material - Maximum Operating Temperature
1
Alumina - 2912°F (1600°C) maximum - 1.25 NPT mounting
2
Inconel Alloy - 1832°F (1000°C) maximum - 1.25 NPT mounting
Code
Mounting Adapter- Stack Side
0
No adapter plate required uses 1.25 NPT
("0" must also be chosen under "Mounting Adapter" below)
1
New flanged installation - Square weld plate with studs (matches "Mounting Adapter" below)
2
Model 450 mounting ("4" must also be chosen under "Mounting Adapter" below)
3
Competitor's Mount ("5" must also be chosen under "Mounting Adapter" below)
Code
Mounting Adapter - Probe Side
0
No adapter plate
1
ANSI 2 in. 150 lb flange to 1.25 NPT adapter
(6 in. dia. flange, 4.75 in. BC with 4 x 0.75 in. dia. holes)
2
DIN to 1.25 NPT adapter (184 mm flange, 145 mm BC with 4 x 18 mm dia. holes)
3
JIS to 1.25 NPT adapter (155 mm flange, 130 mm BC with 4 x 13 mm dia. holes)
4
Model 450 to 1.25 NPT adapter
5
Competitor's mounting flange
Code
Electronics & Housing TYPE 4X, IP65
H1
5081-G HART Electronics – ATEX/IECEx
H2
5081-G HART Electronics - CSA
H3
5081-G HART Electronics - FM
Code
Housing Mounting
1
Surface or wall mounting
2
1/2 to 2 in. pipe mounting
Code
Communications
1
No remote control
2
Infrared Remote Control (IRC)
(LCD display through cover window
Code
Calibration Accessories
1
No hardware
2
Calibration and reference air flowmeters and
reference air pressure regulator
Code
Armored Cable Length
00
No cable
11
20 ft (6 m)
12
40 ft (12 m)
13
60 ft (18 m)
14
80 ft (24 m)
15
100 ft (30 m)
16
150 ft (45 m)
17
200 ft (61 m)
18
300 ft (91 m)
19
400 ft (122 m)
20
500 ft (152 m)
5081FG
2
1
0
0
1
1
1
2
11
Example
Summary of Contents for Rosemount 5081FG
Page 2: ......
Page 6: ...Reference Manual 00809 0100 4882 Rev AB June 2019 Rosemount 5081FG TOC 4 ...
Page 20: ...Reference Manual 00809 0100 4882 Rev AB May 2019 Rosemount 5081FG 1 10 ...
Page 36: ...Reference Manual 00809 0100 4882 Rev AB May 2019 Rosemount 5081FG 2 16 ...
Page 53: ...Reference Manual 00809 0100 4882 Rev AB May 2019 Rosemount 5081FG 3 17 Figure 3 20 Show Fault ...
Page 82: ...Reference Manual 00809 0100 4882 Rev AB May 2019 Rosemount 5081FG 6 6 ...
Page 94: ...Reference Manual 00809 0100 4882 Rev AB May 2019 Rosemount 5081FG A 8 ...
Page 96: ...Reference Manual 00809 0100 4882 Rev AB June 2019 Rosemount 5081FG B 2 ...
Page 98: ...Reference Manual 00809 0100 4882 Rev AB June 2019 Rosemount 5081FG B 2 ...
Page 100: ......
Page 103: ...Index 2 ...