Equation 3-1: Chord “L” Dimension
L
cℎord
= L
MeterHousing
+ L
Mount1
+ L
Mount2
−L
Xdcr1
− L
Stalk1
− L
Hldr1
−L
Xdcr2
− L
Stalk2
− L
Hldr2
L
chord
= chord “L” dimension (in) (
LA ... LD
)
L
MeterHousing
= meter housing length (in)
L
Mount1
= transducer 1 mount length (in)
L
Mount2
= transducer 2 mount length (in)
L
Xdcr1
= transducer 1 length (in)
L
Xdcr2
= transducer 2 length (in)
L
Stalk1
= transducer 1 stalk length (in)
L
Stalk2
= transducer 2 stalk length (in)
L
Hldr1
= transducer 1 holder length (in)
L
Hldr2
= transducer 2 holder length (in)
Tip
The transducer “L” dimension is re-calculated when you run the Transducer Swap-out
utility.
3.3
T-Slot transducer holder removal and
installation
WARNING
CONTENTS MAY BE UNDER PRESSURE
When the meter is under pressure, DO NOT attempt to remove or adjust the transducer
holder of the T-Slot transducer assembly, or loosen the screws holding the T-200
transducer assembly.
Attempting to do so could release pressurize gases, resulting in serious injury or
equipment damage.
WARNING
CONTENTS MAY BE HAZARDOUS
The meter must be fully depressurized and drained before attempting to remove the
T-200 transducer assembly. If gas or fluid begins to leak from the T-200 transducer stalk
assembly, stop immediately and reinstall T-200 stalk assembly.
Failure to comply could cause serious injury or equipment damage.
A. Transducer holder
Meter repairs
Maintenance and Troubleshooting Manual
April 2022
00809-0600-3104
54
Emerson.com/Rosemount