Table 6-2: Failure Alerts (F:)
Message
Description
Recommended actions
Electronics Failure
An electronics error that could impact
the device measurement reading has
occurred.
1. Restart the device.
2. Restore the default settings and
reconfigure device.
3. If the condition persists, replace
the device.
Radio Failure
The wireless radio has detected a
failure or stopped communicating.
1. Restart the device.
2. If the condition persists, replace
the device.
Critical Power Failure
The supply voltage is too low and will
affect Device Operation.
•
Replace the Power Module, see
Probe Disconnected
The device cannot detect the probe.
1. Check that the probe connection
is properly tightened.
2. Check that the probe connection
is dry and clean.
3. Restart level measurements.
4. If the condition persists, replace
the device and/or the probe.
Electronics Temperature Critical
The internal temperature of the device
has reached critical levels and the
integrity of the device electronics may
be compromised. Environmental
temperature should not exceed device
specifications.
1. Verify that ambient temperature
is within the specified range. For
more information about the
maximum ambient temperature,
see
.
2. Remote mount the transmitter
head away from the process and
environmental conditions.
3. Restart the device.
4. If the condition persists, replace
the device.
Remote Housing Error
The device has detected a problem
associated with the remote housing.
1. Correct remote housing
configuration to match
connected remote housing cable.
2. Check remote housing cable.
Configuration Error
The device has detected a
configuration error. Reasons may be
multiple.
See
for a list of detailed
Configuration Errors that may be
displayed.
1. Click on the Details button for
more information.
2. Correct the parameter causing
the configuration error.
Reference Manual
Service and troubleshooting
00809-0100-4308
February 2020
Reference Manual
109
Summary of Contents for Rosemount 3308A
Page 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Page 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Page 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Page 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Page 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...