Reference Manual
00809-XXXX-4811, Rev AA
February 2012
Rosemount 3308
6-10
PRELIMINARY
POWER MODULE
REPLACEMENT
Expected Power Module life is
XX
years at reference conditions
(1)
.
Add warnings
When the Power Module needs to be replaced, remove the Power Module
cover and the depleted Power Module. Replace the power module with a new
Black Power Module, SmartPower™ Solutions model number 701PBKKF.
Replace the cover and ensure that the power module cover is fully tightened
to prevent moisture ingress. The lip of the power module cover should be in
contact with the metal enclosure to ensure a proper seal. Do not over tighten.
Handling Considerations
The Black Power Module with the wireless unit contains two "C" size primary
lithium/thionyl chloride batteries. Each battery contains approximately 2.5
grams of lithium, for a total of 5 grams in each Power Module. Under normal
conditions, the battery materials are self-contained and are not reactive as
long as the batteries and the battery pack integrity are maintained. Care
should be taken to prevent thermal, electrical or mechanical damage.
Contacts should be protected to prevent premature discharge.
Use caution when handling the power module, it may be damaged if dropped
from heights in excess of 20 ft (6 m).
Battery hazards remain when cells are discharged.
Environmental Considerations
As with any battery, local environmental rules and regulations should be
consulted for proper management of spent batteries. If no specific
requirements exist, recycling through a qualified recycler is encouraged.
Consult the materials safety data sheet for battery specific information.
Shipping Considerations
The unit was shipped to you without the power module installed. Please
remove the power module prior to shipping.
Each Black Power Module contains two "C" size primary lithium batteries.
Primary lithium batteries are regulated in transportation by the U.S.
Department of Transportation, and are also covered by International Air
Transport Association (IATA), International Civil Aviation Organization (ICAO),
and European Ground Transportation of Dangerous Goods (ARD). It is the
responsibility of the shipper to ensure compliance with these or any other
local requirements. Please consult current regulations and requirements
before shipping.
(1) Reference conditions are 70° F (21° C), transmit rate of once per minute, and routing data
for three additional network devices.
Summary of Contents for Rosemount 3308
Page 2: ...PRELIMINARY ...
Page 8: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 TOC 4 PRELIMINARY ...
Page 12: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 1 4 PRELIMINARY ...
Page 26: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 2 14 PRELIMINARY ...
Page 34: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 3 8 PRELIMINARY ...
Page 54: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 4 20 PRELIMINARY ...
Page 102: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 7 22 PRELIMINARY ...
Page 127: ...PRELIMINARY ...