Reference Manual
00809-XXXX-4811, Rev AA
February 2012
5-13
Rosemount 3308
PRELIMINARY
VOLUME
CONFIGURATION
Transmitter Variables
Select the Volume option in order to configure the transmitter for volume
measurements.
Volume Units
Choose one of the following units:
• Gallons
• Liters
• Imperial Gallons
• Cubic Meters
• Barrels
• Cubic Yards
• Cubic Feet
• Cubic Inch
Tank Type
Choose a standard tank shape, or select the strapping option. Standard
shapes are: Vertical Cylinder, Horizontal Cylinder, Vertical Bullet, Horizontal
Bullet or Sphere. (If Primary Variable is Level choose None for Tank Type).
If your tank does not correspond to any of the above tank shapes, select Strap
Table.
Tank Dimensions
If a standard tank type was chosen, enter the diameter and height of the tank.
See “Volume Configuration” on page 5-6 for information on how to specify
tank dimensions.
Strapping Table
If tank type Strapping Table was chosen, enter how many entries you will use
and the actual level and volume points. You can enter from 2 to 10 points. The
strapping points must be entered such that the first point corresponds to the
lowest level, and the last point corresponds to the topmost level of the tank.
HART Comm
TO BE
ADDED
HART Comm
TO BE
ADDED
HART Comm
TO BE
ADDED
HART Comm
TO BE
ADDED
HART Comm
TO BE
ADDED
Summary of Contents for Rosemount 3308
Page 2: ...PRELIMINARY ...
Page 8: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 TOC 4 PRELIMINARY ...
Page 12: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 1 4 PRELIMINARY ...
Page 26: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 2 14 PRELIMINARY ...
Page 34: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 3 8 PRELIMINARY ...
Page 54: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 4 20 PRELIMINARY ...
Page 102: ...Reference Manual 00809 XXXX 4811 Rev AA February 2012 Rosemount 3308 7 22 PRELIMINARY ...
Page 127: ...PRELIMINARY ...