3.3.5
Service fuctions
This section provides instructions for viewing and managing parameters.
View the highest and lowest measured pressure
The pressure transmitter saves the highest and lowest measured preasure values. Follow
these steps to view the highest and lowest pressure values previously measured by the
pressure transmitter.
Procedure
1. To view the maximum pressure value, select
HI
from the extended functions menu.
2. To view the minimum pressure value, select
LO
from the extended functions menu.
Deleting high and low pressure memory
Follow these steps to clear the highest and lowest pressure readings on the pressure
transmitter.
Procedure
1. Select
HI
or
LO
from the extended functions menu.
2. Press and hold
Set
until the pressure transmitter displays
---
.
3. Press
Mode/Enter
.
Resetting all parameters to factory default settings
Follow these steps to reset all of the parameters to the factory default settings.
Prerequisites
Before resetting the parameters, record the current parameters using
Procedure
1. Select
rES
from the extended functions menu.
2. Press and hold
Set
until the pressure transmitter displays
---
.
3. Press
Mode/Enter
.
3.3.6
Simulation function
During a simulation, the pressure transmitter replicates error conditions for testing
purposes. This section includes instructions for using the simulation function.
Open the simulation menu
Open the simulation menu to view simulation options and parameters.
Procedure
1. Select
EF
from the menu.
2. Press
Set
.
Operation
Quick Start Guide
January 2019
00825-0100-4327
30
Quick Start Guide
Summary of Contents for Rosemount 326P
Page 1: ...Quick Start Guide 00825 0100 4327 Rev 01 January 2019 Rosemount 326P Pressure Transmitter ...
Page 2: ...2 ...
Page 4: ...Contents Quick Start Guide January 2019 00825 0100 4327 4 Quick Start Guide ...
Page 14: ...Installation Quick Start Guide January 2019 00825 0100 4327 14 Quick Start Guide ...
Page 40: ...Setting ranges Quick Start Guide January 2019 00825 0100 4327 40 Quick Start Guide ...
Page 44: ...Product certifications Quick Start Guide January 2019 00825 0100 4327 44 Quick Start Guide ...
Page 47: ...Quick Start Guide 00825 0100 4327 January 2019 Quick Start Guide 47 ...