24
Reference Manual
00809-0100-2460, Rev DE
October 2018
3.3.1
Installation plan
It’s a good idea to make a plan of the installation in order to ensure that all components in the system are
properly specified. The plan should include the following:
suitable locations for devices
power budget
cabling and connections (for example whether devices will be “daisy-chained” or not)
specification of cable glands for the various devices
location of terminators on the Tankbus (Rosemount 2410 Tank Hub)
identification codes such as Unit ID/Device ID of each device
assigned communication addresses for level gauges and other field devices to be stored in the Tank
Databases
(1)
of the Rosemount 2460 System Hub and Rosemount 2410 Tank Hub
“Electrical installation” on page 28
for more information on cables and glands.
1.
See the Rosemount Tank Gauging
manual
(Document no. 00809-0300-5100) and the Rosemount 2410 Tank Hub
(Document no. 00809-0100-2410) for more information.
Summary of Contents for Rosemount 2460