159
October 2017
Reference Manual
00809-0100-2240, Rev DA
70
PD_TAG
PD tag description of device.
71
DEV_STRING
This is used to load new licensing into the device. The value can be
written but will always read back with a value of 0.
72
DEV_OPTIONS
Indicates which miscellaneous device licensing options are
enabled.
73
OUTPUT_BOARD_SN
Output board serial number. For the Rosemount 2230 Display this
is the same as Main Label Device ID which can be found on the main
label that is attached to the housing.
74
FINAL_ASSY_NUM
Final assembly number given by manufacturer.
75
DOWNLOAD_MODE
Gives access to the boot block code for over-the-wire downloads.
0 = Uninitialized
1 = Run mode
2 = Download mode
76
HEALTH_INDEX
Parameter representing the overall health of the device, 100 being
perfect and 1 being non-functioning. The value is based on the
active PWA alarms.
77
FAILED_PRI
Designates the alarming priority of the FAILED_ALM and also used
as switch b/w FD and legacy PWA. If value is greater than or equal
to 1 then PWA alerts will be active in device else device will have FD
alerts.
78
RECOMMENDED_ACTION
Enumerated list of recommended actions displayed with a device
alert.
79
FAILED_ALM
Alarm indicating a failure within a device which makes the device
non-operational.
80
MAINT_ALM
Alarm indicating the device needs maintenance soon. If the
condition is ignored, the device will eventually fail.
81
ADVISE_ALM
Alarm indicating advisory alarms. These conditions do not have a
direct impact on the process or device integrity.
82
FAILED_ENABLE
Enabled FAILED_ALM alarm conditions. Corresponds bit for bit to
the FAILED_ACTIVE. A bit on means that the corresponding alarm
condition is enabled and will be detected. A bit off means the
corresponding alarm condition is disabled and will not be detected.
This parameter is the Read Only copy of FD_FAIL_MAP.
83
FAILED_MASK
Mask of FAILED_ALM. Corresponds bit of bit to FAILED_ACTIVE. A
bit on means that the condition is masked out from alarming.
This parameter is the Read Only copy of FD_FAIL_MASK.
84
FAILED_ACTIVE
Enumerated list of failure conditions within a device. All open bits
are free to be used as appropriate for each specific device.
This parameter is the Read Only copy of FD_FAIL_ACTIVE.
85
MAINT_PRI
Designates the alarming priority of the MAINT_ALM
86
MAINT_ENABLE
Enabled MAINT_ALM alarm conditions. Corresponds bit for bit to
the MAINT_ACTIVE. A bit on means that the corresponding alarm
condition is enabled and will be detected. A bit off means the
corresponding alarm condition is disabled and will not be detected.
This parameter is the Read Only copy of FD_OFFSPEC_MAP
87
MAINT_MASK
Mask of MAINT_ALM. Corresponds bit of bit to MAINT_ACTIVE. A
bit on means that the condition is masked out from alarming.
This parameter is the Read Only copy of FD_OFFSPEC_MASK.
88
MAINT_ACTIVE
Enumerated list of maintenance conditions within a device.
This parameter is the Read Only copy of FD_OFFSPEC_ACTIVE.
Index
Number
Parameter
Description
Summary of Contents for Rosemount 2240S
Page 2: ......
Page 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Page 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Page 193: ......