Appendix A: Reference Data
June 2012
Specifications and Reference Data
Pressure Testing
Expanded
P1
Hydrostatic Testing with Certificate
Cleaning Process Area
(14)
Expanded
P2
Cleaning for Special Service
P3
Cleaning for <1 PPM Chlorine/Fluorine
Performance
Standard
Standard
P8
(15)
High Performance Option
★
Ground Screw
Standard
Standard
V5
(16)
External Ground Screw Assembly
★
Surface Finish
Standard
Standard
Q16
Surface finish certification for sanitary remote seals
★
Toolkit Total System Performance Reports
Standard
Standard
QZ
Remote Seal System Performance Calculation Report
★
Conduit Electrical Connector
Standard
Standard
GE
M12, 4-pin, Male Connector (eurofast
®
)
★
GM
A size Mini, 4-pin, Male Connector (minifast
®
)
★
Typical Model
Number:
2051T G 5 F 2A 2 1 A B4
(1) 2051TG lower range limit varies with atmospheric pressure.
(2) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(3) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(4) “Assemble-to” items are specified separately and require a completed model number.
(5) Not available with low-power Option Code M.
(6) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges, assemble-to
manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16 code), and remote seal
system report (QZ code).
(7) Only available with HART 4-20 mA output (output code A).
(8) Not available with fieldbus (output code F) or Profibus protocols (output code W).
(9) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified.
(10) Available only with output code W - Profibus PA.
(11) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(12) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(13) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(14) Not valid with Alternate Process Connection S5.
(15) High Performance Option includes 0.04% Reference Accuracy. See
for details.
(16) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.
Table A-6. 2051T In-Line Pressure Transmitter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Summary of Contents for Rosemount 2051 Wireless Series
Page 2: ......
Page 12: ...4 Reference Manual 00809 0100 4102 Rev AA Section 1 Introduction June 2012 Introduction ...
Page 32: ...24 Reference Manual 00809 0100 4102 Rev AA Section 2 Configuration June 2012 Configuration ...
Page 110: ......
Page 113: ......
Page 117: ...iv Reference Manual 00809 0100 4100 Rev AA Title Page June 2012 ...
Page 123: ...x Reference Manual 00809 0100 4100 Rev AA Table of Contents June 2012 Table of Contents ...
Page 167: ...44 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 168: ...45 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 169: ...46 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 249: ......