Procedure
1. Remove the protective cover from the diaphragm of the remote seal. Use extreme
caution during installation to ensure the diaphragm is not damaged.
2. Place the appropriate gasket for the application on the remote seal.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
3. Ensure that the SLS dairy process connection seal is flush with the process
connection.
4. Tighten the nut onto the process connection per DIN 11851. Care should be taken
not to overtighten.
Note
EHEDG requirement on T-stub installations: the length (L) divided by the diameter
(D) of the tee is to be less than 1 (i.e. L /D < 1).
D
L
3.23
WSP saddle seal
Figure 3-30: WSP Saddle Seal
3-in. line size and smaller
4-in. line size and larger
A
A
B
B
A. Connection to transmitter
B. Diaphragm
3.23.1
Parts required for installation
The parts required to install the WSP saddle seal will be defined here. Prior to installation,
you will need the following:
Installation
Reference Manual
May 2020
00809-0100-4002
62
Rosemount DP Level
Summary of Contents for Rosemount 1199
Page 4: ...4 ...
Page 8: ...Introduction Reference Manual May 2020 00809 0100 4002 8 Rosemount DP Level ...
Page 22: ...Remote Seal Systems Reference Manual May 2020 00809 0100 4002 22 Rosemount DP Level ...
Page 74: ...Installation Reference Manual May 2020 00809 0100 4002 74 Rosemount DP Level ...
Page 92: ...Fill Fluids Reference Manual May 2020 00809 0100 4002 92 Rosemount DP Level ...