Reference Manual
00809-0100-4235, Rev BA
April 2007
Rosemount 1152
6-6
Overpressure Limits
Rosemount 1152AP and 1152GP:
Operates within specification from 0.5 psia (3.4 kPa abs) to upper range
limit; overpressure limit is 2,000 psig (13.8 MPa) without damage to the
transmitter for all range codes, except Range Code 9, which has a limit of
4,500 psig (31.0 MPa) and Range Code 0, which has a limit of
7,500 psig (51.7 MPa)
PHYSICAL
SPECIFICATIONS
Materials of Construction
Isolating Diaphragms:
316L SST
Drain/Vent Valves:
316 SST
Process Flanges:
CF-8M (Cast version of 316 SST)
O-rings:
Ethylene Propylene
Fill Fluid:
Silicone Oil
Flange Bolts and Nuts:
Plated alloy steel, per ASTM A-540
Electronics Housing:
Low-copper aluminum with epoxy-polyester paint, or authentic stainless
steel
Mounting Bracket:
Carbon steel, AISI 1010 or 1020, with epoxy-polyester paint or 316L SST
Mounting Bolts (Bracket to Transmitter):
SAE J429 carbon steel, Grade 2 or Grade 5
Process Connections
1
/
4
–18 NPT
Electrical Connections
1
/
2
–14 NPT conduit with screw terminals
Weight
12 lb. (5.4 kg) with aluminum housing; 16 lb. (7.3 kg) with stainless steel
housing (excluding bracket)
Summary of Contents for Rosemount 1152 Alphaline
Page 6: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 1 2 ...
Page 10: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 1 2 ...
Page 20: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 2 10 ...
Page 34: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 3 14 ...
Page 40: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 4 6 ...
Page 52: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 5 12 ...
Page 64: ...Reference Manual 00809 0100 4235 Rev BA April 2007 Rosemount 1152 Index 2 ...
Page 65: ......
Page 66: ......
Page 67: ......