Emerson ODYSSEY CF2455BS00 Owner'S Manual Download Page 7

7

The outlet box and joist must be securely mounted
and capable of supporting at least 50 lbs. Use only a
U.L. outlet box listed as “Acceptable for Fan
Support”.

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET 
BOX

Figure 12

How to Hang

Your Ceiling Fan 

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

Figure 13

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and the
hanger bracket.

WARNING

!

20. Position one fan blade on the flange assembly

and secure by installing the left and right blade
holder caps using two 10-32 x 3/8” pan head
screws (supplied) for each holder cap (Figure 10).
Install the remaining four fan blades using the
same procedure.

LEFT BLADE
HOLDER CAP

FLANGE
ASSEMBLY

10-32 X 3/8"
PAN HEAD SCREW
(2 PER HOLDER CAP)

RIGHT BLADE
HOLDER CAP

Figure 10

21. You have now completed the initial assembly of your

new ceiling fan. You can now proceed with hanging
and wiring your fan.

CEILING

FLOOR

AT LEAST

7'

Figure 11

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 11).

WARNING

!

1. Securely attach the hanger bracket to the outlet box

using the two screws supplied with the outlet box.
(Figure 12.)

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

2. Carefully lift the fan and seat the hanger

ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 13). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 12).

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

Summary of Contents for ODYSSEY CF2455BS00

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Part No F40BP73370000 Form No BP7337 U L Model No CF2455 Model No CF2455BS00 CF2455ORB00 CF2455PW00 ODYSSEY Net Weight 26 0 Lbs 54 Ceiling Fan Owner s Manual ...

Page 2: ...s provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to p...

Page 3: ...ILING COVER FAN BLADES MOTOR COUPLING COVER LIGHT KIT ADAPTER UPLIGHT LEAD ASSEMBLY BLADE HOLDER CAPS LEFT LIGHT KIT PLATE ASSEMBLY SW116 FAN LIGHT WALL CONTROL HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET SW105 RECEIVER LOOSE PARTS BAG LIGHT KIT GLASS DIE CAST GLASS HOLDERS FAN MOTOR AND HOUSING ASSEMBLY BLADE HOLDER CAPS RIGHT HI MED LOW FAN OFF REV EMERSON D L U L Do not install or use fan if an...

Page 4: ...cuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qua...

Page 5: ...CLIP CLEVIS PIN DOWNROD CONNECT YELLOW WIRES USING WIRE CONNECTOR SETSCREW CLEVIS PIN Figure 2 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 9 Position the ceiling cover over the downrod Be sure the cover is oriented correct...

Page 6: ...nector and the one pin connector from the motor shaft Figure 7 17 Securely connect the black wire from the light kit plate assembly to the blue wire from the motor shaft using a wire connector supplied Figure 7 Connect the white wire from the plate assembly to the white wire from the motor shaft using a wire connector supplied SINGLE PIN CONNECTOR SETSCREW COLLAR FOUR PIN CONNECTOR LIGHT KIT ADAPT...

Page 7: ...sing the same procedure LEFT BLADE HOLDER CAP FLANGE ASSEMBLY 10 32 X 3 8 PAN HEAD SCREW 2 PER HOLDER CAP RIGHT BLADE HOLDER CAP Figure 10 21 You have now completed the initial assembly of your new ceiling fan You can now proceed with hanging and wiring your fan CEILING FLOOR AT LEAST 7 Figure 11 The fan must be hung with at least 7 of clearance from floor to blades Figure 11 WARNING 1 Securely at...

Page 8: ...nect the electrical supply circuit before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 14 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 14...

Page 9: ... outlet box push the black blue and yellow wires into the other side of the outlet box Figure 15 Final Assembly 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 16 2 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 17 3 Secure the ceiling cover in place by installing two lockw...

Page 10: ...the stud threads revealed 10 LIGHT KIT ADAPTER LIGHT KIT GLASS KNURLED KNOB SCREW ROTATE LIGHT KIT GLASS COUNTERCLOCKWISE VIEWED FROM TOP Figure 21 12 Your ceiling fan is now installed and wired and ready for use DIE CAST GLASS HOLDER PROTECTIVE COVER ON ADHESIVE BACKED MATERIAL Figure 18 DIE CAST GLASS HOLDER LIGHT KIT GLASS Figure 19 TURN KNURLED KNOB SCREW SEVERAL TURNS INTO THE GLASS HOLDER LI...

Page 11: ... Wall Control and Receiver Figure 22 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scr...

Page 12: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to radio communications However there is not guarantee that interference will not occur in a particular installatio...

Page 13: ... weight and result in smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage t...

Page 14: ...14 4 2 1 3 5 6 7 10 3 11 25 8 7 31 30 29 15 15 20 21 22 23 24 28 27 12 13 14 8 26 9 HI MED LOW FAN OFF REV EMERSON D L U L 17 16 18 17 19 Repair Parts ...

Page 15: ...der 763265 3 763265 7 763265 6 26 Uplight Lead Assembly 761790 761790 761790 Loose Parts Bag containing 763243 763243 1 763243 1 3 Threaded Stud 8 32 x 1 1 4 4 5 Wire Connector 7 6 Setscrew Wrench 5 32 7 Lockwasher 4 8 Knurled Knob 4 11 Clip Hairpin 12 Pin Clevis 13 Setscrew 17 Blade Screw 10 32 x 3 8 21 24 Phillips Head Screw 8 32 x 3 8 3 25 Setscrew Wrench 3 16 27 Knurled Knob Screw 2 28 Jumper ...

Page 16: ...ized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass glob...

Reviews: