Example: Cutoff interaction
Configuration:
•
mA Output Process Variable
=
Mass Flow Rate
•
Frequency Output Process Variable
=
Mass Flow Rate
•
AO Cutoff
=
10
g/sec
•
Mass Flow Cutoff
=
15
g/sec
Result: If the mass flow rate drops below 15 g/sec, all outputs representing mass flow will
report zero flow.
Example: Cutoff interaction
Configuration:
•
mA Output Process Variable
=
Mass Flow Rate
•
Frequency Output Process Variable
=
Mass Flow Rate
•
AO Cutoff
=
15
g/sec
•
Mass Flow Cutoff
=
10
g/sec
Result:
•
If the mass flow rate drops below 15 g/sec but not below 10 g/sec:
-
The mA output will report zero flow.
-
The frequency output will report the actual flow rate.
•
If the mass flow rate drops below 10 g/sec, both outputs will report zero flow.
6.2.4
Configure Added Damping
Display
Not available
ProLink II
ProLink
>
Configuration
>
Analog Output
>
Primary Output
>
AO Added Damp
ProLink III
Device Tools
>
Configuration
>
I/O
>
Outputs
>
mA Output
Field Communicator
Configure
>
Manual Setup
>
Inputs/Outputs
>
mA Output
>
mA Output Settings
>
PV Added Damping
Overview
Damping is used to smooth out small, rapid fluctuations in process measurement.
Damping
Value
specifies the time period (in seconds) over which the transmitter will spread changes
in the reported process variable. At the end of the interval, the reported process variable
will reflect 63% of the change in the actual measured value.
Added Damping
controls the
amount of damping that will be applied to the mA output. It affects the reporting of
mA
Output Process Variable
through the mA output only. It does not affect the reporting of that
process variable via any other method (e.g., the frequency output or digital
communications), or the value of the process variable used in calculations.
Integrate the meter with the control system
Configuration and Use Manual
105
Summary of Contents for MICRO MOTION 2700
Page 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Page 373: ......