You cannot reset inventories while the transmitter is secured.
10.1.1
Approved methods to read or obtain process data
When the Weights & Measures application is installed, process data is approved for
custody transfer use only if an approved method is used for reading or obtaining it.
Note
On the primary mA output, HART/Bell 202 communications may be used to poll for either
temperature or pressure, in conjunction with process data reporting.
NTEP-approved methods to read or obtain process data
Table 10-1:
Process data
mA output(s)
Frequency output(s)
Mass
✓
Volume
✓
Density
✓
Totalizer values
Inventory values
OIML-approved methods to read or obtain process data
Table 10-2:
Process data
mA output(s)
Frequency output(s)
Mass
✓
Volume
✓
Density
✓
Totalizer values
Inventory values
10.1.2
Effect of the Weights & Measures application on process
measurement and outputs
When the Weights & Measures application is installed, process measurement and
reporting is modified to prevent unauthorized use of the data. Specific changes are
controlled by whether the transmitter is secured or unsecured.
Transmitter outputs and process data when Approvals=NTEP
Table 10-3:
Function
Transmitter status
Unsecured
Secured
Outputs
mA output behavior
If reporting a flow variable, mA output reports
zero flow. Otherwise, normal.
Normal
Operate the transmitter with the Weights & Measures application
134
Micro Motion Model 2500 Transmitters with Configurable Input/Outputs
Summary of Contents for Micro Motion 2500
Page 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 237: ...NE 53 history Configuration and Use Manual 229 ...