142
Micro Motion Series 1000 and Series 2000 Transmitters
Troubleshooting
Table 12-6
Process variables problems and possible remedies
Symptom
Cause
Possible remedy
Steady non-zero flow rate under
no-flow conditions
Misaligned piping (especially in new
installations)
Correct the piping.
Open or leaking valve
Check or correct the valve mechanism.
Bad sensor zero
Rezero the meter. See Section 5.5.
Bad flow calibration factor
Verify characterization. See
Section 6.2.
Erratic non-zero flow rate under
no-flow conditions
RF interference
Check environment for RF interference.
See Section 12.14.4.
Wiring problem
Verify all sensor-to-transmitter wiring
and ensure the wires are making good
contact.
Incorrectly grounded 9-wire cable (in
9-wire remote installations and remote
core processor with remote transmitter
installations)
Verify 9-wire cable installation. Refer to
Appendix B for diagrams, and see the
installation manual for your transmitter.
Vibration in pipeline at rate close to
sensor tube frequency
Check environment and remove source
of vibration.
Improper sensor grounding (T-Series
sensors only)
Verify that the sensor is grounded to
earth ground.
Leaking valve or seal
Check pipeline.
Inappropriate measurement unit
Check configuration. See
Section 12.20.
Inappropriate damping value
Check damping configuration.
Slug flow
Plugged flow tube
Check drive gain and tube frequency.
Purge the flow tubes or replace the
sensor.
Moisture in sensor junction box
Open junction box and allow it to dry.
Do not use contact cleaner. When
closing, ensure integrity of gaskets and
O-rings, and grease all O-rings.
Mounting stress on sensor
Check sensor mounting. Ensure:
• Sensor is not being used to support
pipe.
• Sensor is not being used to correct
pipe misalignment.
• Sensor is not too heavy for pipe.
Sensor cross-talk
Check environment for sensor with
similar (±0.5 Hz) tube frequency.
Incorrect sensor orientation
Sensor orientation must be appropriate
to process fluid. See the installation
manual for your sensor.
Summary of Contents for MICRO MOTION 1500
Page 10: ...viii Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 18: ...8 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 24: ...14 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 38: ...28 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 44: ...34 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 64: ...54 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 74: ...64 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 106: ...96 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 172: ...162 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 178: ...168 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 190: ...180 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 268: ...258 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 280: ...270 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 281: ......