Remove a module
Figure 4-1:
Use the handles to remove modules.
4.6
6560 Processor module
The 6560 Processor module provides all data acquisition, data storage, and data
communications functions for the CSI 2600. The 6560 is capable of up to 24 simultaneous,
continuous waveform measurements for detailed Spectral analysis, up to 24 RMS and DC
values for Gross Scan measurements, up to 4 tachometers for machine speed
measurement, and up to 4 discrete state inputs.
Gross Scan values, tachometer values, and digital input states may be combined logically
to determine machine operating state, which may be used to define specific data
acquisition states. The system can be configured to transmit and store data on either time
interval or based on the amount of change of the data values.
The processor module provides 2 100Base-T Ethernet ports and one RS-232 serial port for
system communications and diagnostics. Additional connections are available for the
calibration signal and a dry contact SPDT SysFail relay. This relay is energized when the
Processor CPU successfully boots. On a CPU failure or power loss, the relay will de-
energize.
Hardware configuration: overview
MHM-97453, Rev 1
25
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...