background image

Quick Start Guide / Produktinformation

MHM-97468

NC: 6540-90251

11.12.2012

Rev.: 1.000

Machinery Health™ Monitor

CSI 6500 Configuration Kit

Summary of Contents for Machinery Health CSI 6500

Page 1: ...Quick Start Guide Produktinformation MHM 97468 NC 6540 90251 11 12 2012 Rev 1 000 Machinery Health Monitor CSI 6500 Configuration Kit ...

Page 2: ... may possibly have been damaged during trans port The following parts are included in the scope of delivery and must be contained in the shipment 1 Software CD 2 Product information 3 USB to serial RS232 converter incl 0 7m USB cable 4 Serial connection cable 9 pole Sub D to PS2 5 2pc Subclic SMB cable 3m 6 2pc SMB to BNC Adapter If the contents are incomplete or if any defects are observed a comp...

Page 3: ...e repair service before you can receive an RMA number Pricing for your repair can be obtained from support personnel or by calling your local sales representative Once you have your purchase order call 865 675 4274 for an RMA 2 Once you have received your RMA send your hardware to the appropriate product service center Your hardware package should include G RMA Number plus Purchase Order if applic...

Page 4: ...act Email Please describe the problem you are experiencing If we are to send the return shipment to someone other than the Contact Name Addressabove please provide that address here including Con tact Name and Phone Number Are there any special instructions regarding the return Please provide invoice address if a purchase order was required Support customers your instrument is shipped back to you ...

Page 5: ...ts mögli cherweise beschädigt wurde Folgende Teile gehören zum Lieferumfang und müssen in der Sendung enthal ten sein 1 Software CD 2 Produktinformation 3 USB zu Seriell RS232 Konverter incl 0 7m USB Kabel 4 Konfigurationskabel 9 polig Sub D PS2 5 2 Stück Subclic SMB Kabel 3m 6 2 Stück SMB zu BNC Adapter Wenn der Inhalt unvollständig ist oder wenn irgend welche Defekte wahrgenommen werden muss die...

Page 6: ...r für die Kosten der Reparatur angeben bevor sie eine RMA Nummer erhalten Eine Preiskalkulation für die Reparatur können sie vom Service Personal oder von ihrem zuständigen Vertriebsagenten erhalten Wenn sie die Bestellung für eine Reparatur vorliegen haben rufen sie die Nummer 865 675 4274 um eine RMA Nummer zu erhalten 2 Haben sie eine RMA Nummer erhalten schicken sie das Gerät zu dem zuständige...

Page 7: ...l Beschreiben sie bitte ihr Problem Wenn die Rücksendung zu einer anderen Adresse als zur oben Kontak tadresse erfolgen soll bitte geben sie diese hier an einschliesslich Ans prechpartner und Telefonnummer Gibt es spezielle Anweisungen hinsichtlich der Rücksendung Bitte geben sie die Rechnungsadresse an wenn eine Bestellung erforder lich war Hinweis für Kunden Ihr Gerät wird auf dem gleichen Weg z...

Page 8: ...al injury ANSI Z 535 6 DANGER Safety and warning notes are marked with this symbol Non observance of such notes may lead to damages to property or injuries to persons Symbolerklärung HINWEIS Dieses Symbol kennzeichnet Textstellen die wichtige und nützliche Informationen enthalten VORSICHT Hinweise die bei Nichtbeachtung zu Funktionsstörungen und Fehlmessungen führen ohne das Gerät zu beschädigen s...

Page 9: ...l Data 7 1 5 1 Subclic SMB cable 7 1 5 2 Serial configuration cable 7 1 5 3 SMB to BNC adapter 8 1 5 4 USB to RS232 converter 8 Kapitel 2 Deutsch 9 2 1 Lieferumfang 9 2 2 Systemvoraussetzungen 10 2 3 Installationsanweisung 11 2 3 1 Installation der CSI Konfigurationssoftware 11 2 3 2 Starten der Konfigurationssoftware 13 2 3 3 Zusätzliche Informationen zur Installation 14 2 4 Lesen und Drucken der...

Page 10: ...Quick Start Guide Produktinformation NC 6540 90251 Content Inhalt 11 12 2012 Content Inhalt ii ...

Page 11: ...B cable 3m 2 SMB to BNC adapter Besides the CSI 6500 Configuration Software the CD contains software for the MMS 3000 sys tem and MMG 520 as well as the MMS 6855 Sever Requester For the CSI 6500 Configura tion Software a start menu entry will be generated during the installation procedures All other programs can be found after standard installation in the folder C Program Files Emerson Process Man...

Page 12: ...ccordance to the requirements of the operating system Unallocated hard disc min 300 MB OS Windows XP SP2 or Windows 7 32Bit 64Bit Drive CD ROM Keyboard and Mouse Microsoft or Microsoft compatible devices RS 232 Interface One unallocated serial RS232 Interface or alternatively one unalloc ated USB 2 0 Interface for use of the USB to RS232 Converter within scope of delivery Recommended settings of t...

Page 13: ...ons and place the CD into the CD ROM drive of your computer Open the CD and start the file index html A browser window with the following graphic will be displayed Figure 1 Menu of the SW CD Start the installation by clicking on Install CSI 6500 Configuration and follow the instructions that are displayed on the screen During the installation process all programs listed in Table 2 will be installe...

Page 14: ...ntinuously the availability of dongle If the dongle is not recognized the server requester will be abor ted NOTICE If the server requester MMS 6855 is used together with the process management sys tem AMS Asset Graphics the server requester can be unlocked in the AMS Asset Graph ics dongle In this case an additional dongle is not necessary If necessary the dongle driver can be installed later Afte...

Page 15: ...software by double clicking the icons on the desktop Figure 3 or by choosing the software from the program folder Start Programs Emerson Process Management CSI 6500 Configuration Figure 3 Desktop Icon All programs listed in Table 2 can be started by a double click on the respective exe file C Program Files Emerson Process Management CSI 6500 Configuration after standard in stallation ...

Page 16: ... of ID and password is case sensitive The access level Operator provides all necessary rights for configuration and operation of the monitors NOTICE It s recommended to change the predefined log in details for the level Operator after the first log in via the user administration menu Options User Administration Figure 4 Window User Log in 1 3 3 Additional information for installation Potentially n...

Page 17: ... not installed on the computer then it can be downloaded from the Internet and installed To do this go to the Internet address http www adobe com 1 5 Technical Data Only information with tolerances and limit values are considered as binding data Data without tolerances or error limits are provided for information only We reserve the right to make technical changes particularly to the software If n...

Page 18: ...onnector connector Output BNC 1 5 4 USB to RS232 converter USB to RS232 converter Specification Spectra 112315 USB to RS 232 converter Length of the included USB connection cable approx 0 7m Serial connection Sub D 9 pole male Connection to PC USB 2 0 compatible to USB 1 1 Baud rate Up to 115 2 kbps Driver Windows XP Windows7 32 64Bit Support Hardwarehandshake and Remote Wake up ...

Page 19: ...2 SMB zu BNC Adapter Neben der CSI 6500 Konfigurationssoftware enthält die CD auch Software für das MMS 3000 System und den MMG 520 sowie die MMS 6855 Server Requester Software Für die CSI 6500 Konfigurationssoftware wird während der Installation ein Eintrag in das Startmenü er stellt Alle anderen Programme befinden sich nach der Standardinstallation im Verzeichnis C Programme Emerson Process Mana...

Page 20: ...rechend den Systemvoraussetzungen des Betriebssystems freier Festplattenspeicher mindestens 300 MB Betriebssystem Windows XP SP2 oder Windows 7 32Bit 64Bit Laufwerk CD ROM Keyboard und Maus Microsoft oder Microsoft kompatible Geräte RS 232 Schnittstelle Eine freie serielle RS232 Schnittstelle oder alternativ eine freie USB 2 0 Schnittstelle zur Verwerndung des mitgelieferten USB zu RS232 Konverter...

Page 21: ... in das ent sprechende Laufwerk Ihres PCs Laptop Öffnen Sie die CD und starten an schließend die Datei index html Ein Browser Fenster mit dem folgenden Inhalt wird geöffnet Bild Bild 1 Oberfläche der SW CD Starten Sie die Installation durch Anklicken von Install CSI 6500 Configuration und folgen Sie den Installationsanweisungen auf dem Bildschirm Während des Installationsprozesses werden alle in T...

Page 22: ... kontinuierlich ob der Dongle vorhanden ist Wird der Dongle nicht erkannt so wird der Server Requester beendet HINWEIS Wird der Server Requester MMS 6855 zusammen mit der Prozessvisualisierungssoft ware AMS Asset Graphics verwendet kann der Server Requester in dem AMS Asset Graphics Dongle freigeschaltet werden Ein zusätzlicher Dongle ist in dem Fall nicht er forderlich Der Dongle Treiber kann bei...

Page 23: ...tware durch Doppelklick des Icons auf dem Desktop oder durch Auswahl der Software im Programmordner Start Programme Emerson Process Management CSI 6500 Configuration starten Bild 3 Desktop Icon Alle Programme der Tabelle 2 können mit einem Doppelklick auf die entsprechende exe Datei C Programme Emerson Process Management CSI 6500 Configuration nach Stan dardinstallation gestartet werden ...

Page 24: ...ort ist auf die Groß und Kleinschreibung zu achten Die Zugangsebene Bediener beinhaltet alle notwendigen Rechte zur Konfiguration und Be dienung der Monitore HINWEIS Es wird empfohlen die vordefinierten Anmeldedaten für die Zugangsebene Bediener nach dem ersten Anmelden in der Benutzerverwaltung zu ändern Menü Extras Benutzerverwaltung Bild 4 Fenster Benutzeranmeldung 2 3 3 Zusätzliche Information...

Page 25: ... mit dem Acrobat Reader gelesen und gedruckt werden Ist auf dem Rechner kein Acrobat Reader installiert so kann er über das Internet heruntergeladen und installiert werden Öffnen Sie dazu die Internetadresse http www adobe com 2 5 Technische Daten Nur Angaben mit Toleranzen oder Grenzwerten sind verbindliche Daten Daten ohne Tole ranzen bzw ohne Fehlergrenzen sind informative Daten Technische Ände...

Page 26: ...Anschluss Ausgangsseitig BNC 2 5 4 USB zu RS232 Umsetzer USB zu RS232 Konverter Bezeichnung Spectra 112315 USB nach RS 232 Wandler Länge des beiliegenden USB Anschlusskabels ca 0 7m Serieller Anschluss Sub D 9 polig Kupplung Anschluss PC seitig USB 2 0 kompatibel zu USB 1 1 Übertragungsrate bis zu 115 2 kbps Treiber Windows XP Windows7 32 64Bit Unterstützung Hardwarehandshake und Remote Wake up ...

Page 27: ...hanges Änderungsliste 11 12 2012 Quick Start Guide Produktinformation NC 6540 90251 17 Chapter 3 List of Changes Änderungsliste Version Datum Date Änderung Changes 1 000 11 12 2012 Ausgabeversion Release Version ...

Page 28: ... be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available on request We reserve the right to modify or improve the designs or specifications of our products at any time without notice All rights reserved Machinery Health is a mark of one of the...

Reviews: