background image

Emerson Network Power.com

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity

.

AC Power 

Connectivity

DC Power

Embedded Computing

Embedded Power

Monitoring

Outside Plant

Power Switching & Controls

Precision Cooling

Racks & Integrated Cabinets

Services

Surge Protection

Liebert Corporation

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. & 

Canada Only)

614 888 0246 Phone (Outside U.S.)

614 841 6022 FAX

Via Leonardo Da Vinci 8

Zona Industriale Tognana 

35028 Piove Di Sacco (PD)

Italy

39 049 9719 111 Phone 

39 049 5841 257 FAX

Emerson Network Power Asia Pacific

7/F., Dah Sing Financial Centre

108 Gloucester Rd, Wanchai

Hong Kong

852 25722201 Phone 

852 28029250 FAX

liebert.com

24 x 7 Tech Support

800 222 5877 Phone

614 841 6755 (outside U.S.)

Technical Data

Nominal Capacity, 60 Hz 

160 kW / 46 Ton

Nominal Capacity, 50 Hz 

130 kW / 37 Ton

Input Voltage

460 V, 3 ph, 60 Hz

380/415 V, 3 ph, 50 Hz

Full load amps

79 A

Height

78” (1981 mm)

Width

74” (1879 mm)

Depth

34 

5

/

8

” (879mm)

Weight, empty

1800 lbs (817 kg)

The indoor Liebert Refrigerant Chiller is specifically designed to

support the Liebert XD cooling modules. The XDC connects

directly to the modules through the pumped refrigerant. 

When a building chilled water system is available, the Liebert XDP

Pumping Unit is utilized as an interface between the pumped

refrigerant circuit and the chilled water system.  Both the XDC

and the XDP units circulate the refrigerant to the XD modules,

while maintaining the refrigerant at a temperature always above

the actual dewpoint.

Liebert XD Hydraulic System Schematic

While every precaution has been taken to ensure accuracy and 

completeness in this literature, Liebert Corporation assumes no

responsibility, and disclaims all liability for damages resulting

from use of this information or for any errors or omissions.

© 2007 Liebert Corporation. All rights reserved throughout 

the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks

of their respective owners.

® Liebert and the Liebert logo are registered trademarks 

of the Liebert Corporation.

SL-16670 (R12/07)         Printed in USA

Business-Critical Continuity, Emerson Network

Power and the Emerson Network Power logo

are trademarks and service marks of Emerson

Electric Co. ©2007 Emerson Electric Co.

Liebert

Heat

Rejection

Liebert

XDC

Refrigerant 

Chiller

Liebert

XDC

Refrigerant 

Chiller

Pumped

Refrigerant

Pumped

Refrigerant

XD Cooling Module/Rack

XD Cooling Module/Rack

XD Cooling Module/Rack

XD Cooling Module/Rack

Direct system configuration

Building

Chilled

Water

Liebert

XDP

Liebert

XDP

Pumped

Refrigerant

Pumped

Refrigerant

Indirect system configuration

XD Cooling Module/Rack

XD Cooling Module/Rack

XD Cooling Module/Rack

XD Cooling Module/Rack

Reviews: