S600+ Instruction Manual
Revised July-2017
I/O
4-27
Figure 4-33. HART Device and Handheld Communicator Beyond the IS Barrier
Figure 4-34. HART Device without Handheld Communicator
4.4
Mezzanine Module (P148)
The mezzanine module (P148) can be fitted to the Prover or the I/O
module (see
Figure 4-2
), and provides pulse inputs. When used on the
I/O module, it affects pulses 1 and 4; when used on the Prover module,
it affects pulses 2 and 5. The factory fits I/O modules with a mezzanine
module, although you can order an additional mezzanine module for a
Prover module or move the mezzanine module from your I/O module
to your Prover module, depending on your circumstance and needs.
Typically, the mezzanine module supports master meter provers, but
can be employed for other provers as well.