Introduction
This Installation Guide provides instructions for
installation, startup and adjustment. To receive a copy of
the Instruction Manual, contact your local Sales Office or
view a copy at www.fisher.com. For further information
refer to: Type HSR Instruction Manual D103074X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin:
D103053X012
.
SIZE,
Dn / nPS
BODY
MATERIAL
EnD
COnnECTIOn
STYLE
PED
LIMITATIOn
PED
CATEGORY
20, 25 /
3/4, 1
All
All
- - - -
SEP
Specifications
Body Sizes (Inlet x Outlet) and
End Connection Styles
3/4, 3/4 x 1 and 1 NPT
All sizes available in Globe or Angle body
Allowable Inlet Pressures
(1)
Emergency:
10.3 bar / 150 psig
Maximum Operating Pressure:
See Table 1
Allowable Outlet Pressures
(1)
Emergency (Casing):
1.7 bar / 25 psig
Maximum Operating Pressure to Avoid Internal
Parts Damage:
0.21 bar / 3 psi differential above
outlet pressure setting
Outlet Pressure Ranges
See Table 2
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive
Temperature Capabilities
(1)
-29 to 71°C / -20 to 160°F
Installation
!
WARnInG
Personal injury, equipment damage
or leakage due to escaping gas or
bursting of pressure-containing parts
might result if these regulators are
overpressured or installed where service
conditions could exceed the limits for
which the regulators were designed,
or where conditions exceed any
ratings of the adjacent piping or piping
connections. To avoid such injury or
damage, provide pressure-relieving or
pressure-limiting devices (as required
by the appropriate code, regulation or
standard) to prevent service conditions
from exceeding those limits.
Additionally, physical damage to a
regulator could cause personal injury
and property damage due to escaping
gas. To avoid such injury and damage,
install the regulator in a safe location.
A regulator may vent some gas to the
atmosphere in hazardous or flammable
gas service, vented gas might
accumulate and cause personal injury,
death or property damage due to fire or
explosion. Vent a regulator in hazardous
gas service to a remote, safe location
away from air intakes or any hazardous
location. The vent line must be protected
against condensation or clogging.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
ORIfICE SIZE
MAxIMuM OPERATInG InLET
PRESSuRE TO OBTAIn GOOD
REGuLATInG PERfORMAnCE
mm
In.
bar
psig
3.2
4.8
6.4
9.5
13
1/8
3/16
1/4
3/8
1/2
8.6
6.9
4.1
2.1
1.4
125
100
60
30
20
Table 1.
Maximum Operating Inlet Pressure
Type HSR
Installation Guide
D103074X014
English – February 2014
VCIGD-11698-EN.indd 1
2/22/2019 7:46:24 PM