Reassembly
• Perform the above operations in reverse order (respect
tightening torques)
• Replace the O-rings and diaphragm at each disassembly
Slam Shut Reassembly (Version with slam shut)
• The valve plug should be held in an upper position using
a packing gland and a box to facilitate reassembly
• Precaution must be taken concerning the passage of the
valve plug over the segments
Maintenance (continued)
• Lubricate screws before tightening
• Lightly lubricate the O-rings (silicone grease) except for
the valve plug O-ring
• Lightly lubricate the stem (silicone grease)
• Lubricate the release relay mechanism (yoke and bolt)
(molybdenum graphite grease)
• Lubricate the BMS spring (molybdenum graphite grease)
• A special tool is required for reassembling a new orifice
Type EZR
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
Emerson Automation Solutions
Europe, Middle East and
Africa Only
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacific
Singapore 128461, Singapore
T +65 6770 8337
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D103681X012 © 2009, 2017 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 12/17.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specifications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.