![Emerson Fisher C1 Instruction Manual Download Page 42](http://html.mh-extra.com/html/emerson/fisher-c1/fisher-c1_instruction-manual_104612042.webp)
Instruction Manual
D103292X012
C1 Controllers and Transmitters
March 2017
42
Figure 22. Typical Reverse Acting Fisher C1 Assembly
(Refer to figure 26 for the Front View of the Case & Cover Assembly)
RELAY ASSEMBLY
SUBASSEMBLY
(KEY NOS. SHOWN
IN FIGURE 24 OR 25)
NOTE:
KEYS 11, 21, AND 29 ARE NOT SHOWN
GE34729-B
GE31719-A
E1069
OPTIONAL PROCESS PRESSURE INDICATION
TRANSMITTER
SPRING-OUT CLEANING WIRE
Key
Description
5*
Bourdon Tube
6
Dial, aluminum
7
Screw, nylon (transmitters only)
8*
Cantilever Spring, S30200
3-15 psi range
6-30 psi range
9
Nameplate, aluminum
10
Control Pressure Block
For gauge pressure instruments
w/o process pressure gauge
CF8M FMS 20B58 for standard, NACE and oxygen service
w/process gauge
SST
Key
Description
11
Plug, S31600 (not shown)
used with gauge pressure only
1 req'd for standard/NACE
2 req'd for oxygen service
12
Machine Screw, steel pl (4 req'd)
13
Lockwasher, steel pl/zn pl (4 req'd)
14
Pressure Connection, S31600
Use w/process gauge
15
Pipe Plug, steel pl
(not shown)
Use w/process gauge, not used w/Bourdon tube protector
*Recommended spare parts